Feasibility, reliability and validity of self-measurement of knee range-of-motion using an accelerometer-based smartphone application by patients with total knee arthroplasty
PLOS ONE · 03.10.2024 · 19 (10) · e0307219
DOI: 10.1371/journal.pone.0307219 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 03.10.2024. Verfasst von Eleanor Shuxian Chew und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Singapore General Hospital, Singapore, Singapore. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Smartphone, Range of Motion, Articular, Mobile Applications. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SingHealth Regional Health System (RHS): Population-based, Unified, Learning System for Enhanced and Sustainable Health, SingHealth Group Allied Health.
Abstract (Originalsprache)
Aims
Limited knee range-of-motion (ROM) is common following total knee arthroplasty (TKA). It is associated with functional limitations and patient dissatisfaction. Regular knee ROM assessment is important but accurate testing traditionally requires timely access to trained healthcare professionals. Although accelerometer-based smartphone goniometry has shown to provide reliable and valid joint angles, current evidence of its use still positions healthcare providers as end users instead of patients themselves. Therefore, to maximize the impact of smartphone goniometry on post-TKA care, our study aimed to examine the feasibility, reliability, and validity of patients’ self-measurement of knee ROM using an accelerometer-based smartphone goniometry application.
Methods
Patients were given standard instructions with a practice trial before the actual measurements. Passive knee flexion and extension ROM was measured on 2 sessions in 30 patients with TKA using 4 block-randomized methods: (i) smartphone self-assessment, (ii) long-arm goniometry by physiotherapist, (iii) smartphone assessment by physiotherapist, and (iv) extendable-arm goniometry by physiotherapist with placement adjudication. Feasibility was assessed by the number of participants who could independently perform the self-measurement. To assess intra- and inter-session reliability, we computed intraclass correlation coefficients (ICCs) from random-effects models. To assess intra- and inter-session agreement, we computed mean absolute differences (MADs) and minimum detectable change (MDC). To assess concurrent validity, we designated extendable-arm goniometry as the "gold standard" and compared other methods against it using ICCs and MADs.
Results
All patients were able to comprehend and execute the assessment. 87% (n = 26) found the application easy to administer. Smartphone goniometry by patients showed excellent intra- and inter-session reliability (ICCs>0.97) and minimum variability (MAD = 0.9°-3.9°; MDC 95 = 3.1°–9.0°). Smartphone or long-arm goniometry by physiotherapists did not outperform patients’ self-assessment (ICC = 0.96–0.99, MAD = 0.7°-3.1°; MDC 95 = 2.2°-8.0°). Compared against extendable-arm goniometry, smartphone goniometry by patients measured knee flexion and extension ROM with a MAD of 4.5° (ICC, 0.97) and 2.2° (ICC = 0.98), respectively.
Conclusion
Our study demonstrates that smartphone goniometry is feasible, reliable and accurate, and can be used with confidence in the self-assessment of knee ROM post-TKA. Future studies should further explore its utility in telemonitored rehabilitation, and its possible integration into mobile health applications to enhance accessibility to care following TKA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Physiotherapy, Singapore General Hospital, Singapore, Singapore.
- School of Allied Health Care, Curtin University, Perth, Australia.
- School of Computing, National University of Singapore, Singapore, Singapore.
- Programme in Health Services and System Research, Duke-NUS Medical School, Singapore, Singapore.
- Department of Orthopedic Surgery, Singapore General Hospital, Singapore, Singapore.
- Medicine Academic Programme, Duke-NUS Graduate Medical School, Singapore, Singapore.
ORCID-Profile: Eleanor Shuxian Chew, Luke Jonathan Haseler, Yu-Heng Kwan
Förderung
- SingHealth Regional Health System (RHS): Population-based, Unified, Learning System for Enhanced and Sustainable Health
- SingHealth Group Allied Health
Zitieren
APA
Chew, E. S., Woon, E. L., Miao-Shi Low, J. K., Haseler, L. J., Ismail, I., Alif, M. B., Kwan, Y. H., Tan, J. W., Koh, S. S., Pang, H. N., Chen, J. D. Y., Yeo, S. J., Lim, S. Y., Tan, C. I., & Pua, Y. H. (2024). Feasibility, reliability and validity of self-measurement of knee range-of-motion using an accelerometer-based smartphone application by patients with total knee arthroplasty. PLOS ONE, 19(10), e0307219. https://doi.org/10.1371/journal.pone.0307219
Vancouver
Chew ES, Woon EL, Miao-Shi Low JK, Haseler LJ, Ismail I, Alif MB, et al. Feasibility, reliability and validity of self-measurement of knee range-of-motion using an accelerometer-based smartphone application by patients with total knee arthroplasty. PLOS ONE. 2024;19(10):e0307219. doi:10.1371/journal.pone.0307219
BibTeX
@article{Chew2024,
author = {Chew, Eleanor Shuxian and Woon, Ee-Lin and Miao-Shi Low, Juanita Krysten and Haseler, Luke Jonathan and Ismail, Ismahfaris and Alif, Muhammad Bukhari and Kwan, Yu-Heng and Tan, John Wei-Ming and Koh, Samantha Shi-Man and Pang, Hee-Nee and Chen, Jerry Delphi Yongqiang and Yeo, Seng-Jin and Lim, Shi-Ying and Tan, Celia Ia-Choo and Pua, Yong-Hao},
title = {Feasibility, reliability and validity of self-measurement of knee range-of-motion using an accelerometer-based smartphone application by patients with total knee arthroplasty},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {10},
pages = {e0307219},
doi = {10.1371/journal.pone.0307219}
}
EUVIMED