EUVIMEDDescubrir EUVIMED
Crossref

Hydrogel-based electrochemical LAMP sensor for rapid, contamination-free and ultrasensitive point-of-care detection of Vibrio parahaemolyticus

Jing Zhang, Tengyu Li, Ping Zhou, Lihang Zhu, Xingyu Lin, Bin Su

Chemical Communications · 2025

DOI: 10.1039/d5cc01526j ↗

At a glance

Journal article in Chemical Communications, 2025. Written by Jing Zhang and 5 co-authors. Institution: Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, 310058, China. subin@zju.edu.cn. Major MEDLINE topics: Vibrio parahaemolyticus, Nucleic Acid Amplification Techniques, Electrochemical Techniques, Hydrogels. Cited 7 times so far (Crossref); 33 references. Funded by: National Natural Science Foundation of China.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

A portable device was fabricated by integrating a hydrogel-based EC-LAMP sensor with a wireless electrochemical system, realizing the rapid detection of Vibrio parahaemolyticus with a sensitivity down to 2.11 copies per reaction within 15 min.

Subjects

MeSH terms (MEDLINE)

Vibrio parahaemolyticusNucleic Acid Amplification TechniquesElectrochemical TechniquesHydrogelsPoint-of-Care SystemsBiosensing TechniquesLimit of DetectionMolecular Diagnostic Techniques

Substances

Hydrogels

Authors and institutions

  • Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, 310058, China. subin@zju.edu.cn.
  • Department of Clinical Engineering, the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310019, China.
  • College of Biosystems Engineering and Food Science, State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, 310058, China.

Funding

  • National Natural Science Foundation of China

Cite

APA

Zhang, J., Li, T., Zhou, P., Zhu, L., Lin, X., & Su, B. (2025). Hydrogel-based electrochemical LAMP sensor for rapid, contamination-free and ultrasensitive point-of-care detection of Vibrio parahaemolyticus. Chemical Communications. https://doi.org/10.1039/d5cc01526j

Vancouver

Zhang J, Li T, Zhou P, Zhu L, Lin X, Su B. Hydrogel-based electrochemical LAMP sensor for rapid, contamination-free and ultrasensitive point-of-care detection of Vibrio parahaemolyticus. Chemical Communications. 2025. doi:10.1039/d5cc01526j

BibTeX
@article{Zhang2025,
  author = {Zhang, Jing and Li, Tengyu and Zhou, Ping and Zhu, Lihang and Lin, Xingyu and Su, Bin},
  title = {Hydrogel-based electrochemical LAMP sensor for rapid, contamination-free and ultrasensitive point-of-care detection of Vibrio parahaemolyticus},
  journal = {Chemical Communications},
  year = {2025},
  doi = {10.1039/d5cc01526j}
}
Start for free →