FILM-Screen: A fully integrated microfluidic platform for point-of-care lung cancer screening via multiplexed mRNA profiling in blood
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2026.118548 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Qin Huang und 16 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Tsinghua University, Beijing, 100084, China. Hauptthemen laut MEDLINE: Lung Neoplasms, RNA, Messenger, Biomarkers, Tumor, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Natural Science Foundation of Chongqing Municipality, Sichuan Provincial Science and Technology Support Program, China Academy of Space Technology.
Abstract (Originalsprache)
Tumor biomarkers are crucial for early cancer diagnosis. Liquid biopsy via mRNA profiling in blood offers a sensitive and non-invasive approach, but current methods are often complex, time-consuming, expensive, and ill-suited for point-of-care (POC) use. To address these limitations, we developed FILM-Screen, a Fully Integrated Liquid biopsy Microfluidic platform that automates the complete "sample-to-report" workflow. The system uniquely combines syringe-based chemical lysis and bead-based nucleic acid extraction with low-volume (1.41 μL) reverse transcription loop-mediated isothermal amplification (RT-LAMP) in a disposable 24 chambers chip, followed by on-chip, real-time multiplex fluorescence detection. This integrated design enables the simultaneous quantification of up to 22 targets with high sensitivity, achieving a detection limit of 10 copies/μL for RNA. Clinical validation was performed using a 19-mRNA biomarker panel on 65 blood samples. The platform, coupled with an XGBoost classifier, accurately discriminated healthy individuals, patients with benign pulmonary nodules, and lung cancer cases, achieving area under the curve (AUC) values of 0.993, 0.991, and 0.977, respectively. By integrating all steps from sample input to result output, FILM-Screen reduces reagent consumption by approximately 95% compared to standard tube-based methods and completes the analysis within 75 min. It thus represents a sensitive, automated, multiplexed, cost-effective, and portable system for non-invasive lung cancer screening, demonstrating strong potential for deployment in POC and resource-limited settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Biomedical Engineering, Tsinghua University, Beijing, 100084, China.
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu, 610041, China.
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China.
- National Engineering Research Center for Beijing Biochip Technology, Beijing, 102206, China.
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, China; Engineering Research Center of Integrated Acousto-opto-electronic Microsystems (Ministry of Education of China), Beijing Institute o…
- School of Biomedical Engineering, Tsinghua University, Beijing, 100084, China; National Engineering Research Center for Beijing Biochip Technology, Beijing, 102206, China. Electronic address: tshgl@mail.tsinghua.edu.cn.
Förderung
- Natural Science Foundation of Chongqing Municipality
- Sichuan Provincial Science and Technology Support Program
- China Academy of Space Technology
- National Key Research and Development Program of China
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China
- Tsinghua University
- Key Technologies Research and Development Program
Zitieren
APA
Huang, Q., He, Q., Huang, L., Wang, L., Zhao, Q., Mao, Z., Lv, W., Zhong, H., Wang, S., Shi, Y., Zhao, J., Yin, Z., Huang, S., Ma, L., Luo, X., Fu, R., & Huang, G. (2026). FILM-Screen: A fully integrated microfluidic platform for point-of-care lung cancer screening via multiplexed mRNA profiling in blood. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118548
Vancouver
Huang Q, He Q, Huang L, Wang L, Zhao Q, Mao Z, et al. FILM-Screen: A fully integrated microfluidic platform for point-of-care lung cancer screening via multiplexed mRNA profiling in blood. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118548
BibTeX
@article{Huang2026,
author = {Huang, Qin and He, Qiurong and Huang, Leyang and Wang, Lu and Zhao, Qingchen and Mao, ZeYin and Lv, Wenqi and Zhong, Hao and Wang, Shihong and Shi, Yixuan and Zhao, Jianxin and Yin, Ziwei and Huang, Shiguang and Ma, Li and Luo, Xianbo and Fu, Rongxin and Huang, Guoliang},
title = {FILM-Screen: A fully integrated microfluidic platform for point-of-care lung cancer screening via multiplexed mRNA profiling in blood},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2026.118548}
}
EUVIMED