EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori

Rajkumar Rakesh Kumar iD, Chi-Yu Wang, Aditya Manu Bharti iD, Wen-Chian Hu, Yi-Chen Zhang, Ling-Shan Yu iD, Pornnapat Tungtrakarnkul, Kevin C-W Wu, Cheng-Hsin Chuang iD

Analytical Chemistry · 18.11.2025 · 97 (45) · 25148-25157

DOI: 10.1021/acs.analchem.5c04200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.11.2025. Verfasst von Rajkumar Rakesh Kumar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan. Hauptthemen laut MEDLINE: Helicobacter pylori, Graphite, Aniline Compounds, Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Helicobacter pylori (HP) infection is directly associated with over 90% of all gastric cancer (GC) cases. Currently available HP tests are prone to false negatives and are inapt for decentralization. Reliable and user-friendly detection platforms for timely diagnosis and routine monitoring are critical to patient survival. Herein, we targeted this unmet need by developing a novel biosensing platform that strategically combined the robust versatility of electrochemical techniques with the sensitivity and specificity of loop-mediated isothermal amplification (LAMP) to enable the accurate detection of HP at the point-of-care (POC). The biosensor design consisted of an underlying screen-printed carbon electrode (SCPE), sequentially modified with (i) highly conductive acid-functionalized sp2 graphene (Gr) and (ii) needle-like gold microstructures encapsulated with (iii) pH-sensitive polyaniline (PANI), assembled between laser-cut cover layers with a built-in reaction chamber for facile sample handling and detection. LAMP was performed using synthesized primers targeting the HP glmM gene. The amplification inherently generates H+, triggering pH variations, which are precisely tracked by the developed biosensor to simultaneously monitor amplicon growth and quantify HP DNA concentrations via two modes: continuous mode and segmented mode. High sensitivity in a wide linear range (1 to 107 copies/μL) with a limit of detection (LOD) of 1 copy/μL is reported. Furthermore, the excellent correlation with clinical results underscored the practical feasibility of this platform to allow reliable early diagnosis of HP infections and serve as a viable alternative to gastric endoscopy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Helicobacter pyloriGraphiteAniline CompoundsBiosensing TechniquesElectrochemical TechniquesGoldNucleic Acid Amplification TechniquesNanostructuresElectrodesHumansHelicobacter InfectionsLimit of DetectionMolecular Diagnostic Techniques

Substanzen

polyanilineGraphiteAniline CompoundsGold

Autor:innen und Institutionen

  • Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
  • Institute of Biomedical Engineering and Nanomedicine, National Heath Research Institutes, Miaoli 350401, Taiwan.
  • Medical Cosmetic Institution, Kaohsiung Armed Forces General Hospital, Kaohsiung 802301, Taiwan.
  • International PhD Program for Science, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
  • Institute of Biopharmaceutical Science, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
  • Department of Biomedical Engineering, Mahidol University, Nakhon Pathom 73170, Thailand.

ORCID-Profile: Rajkumar Rakesh Kumar, Aditya Manu Bharti, Ling-Shan Yu, Cheng-Hsin Chuang

Zitieren

APA

Kumar, R. R., Wang, C. Y., Bharti, A. M., Hu, W. C., Zhang, Y. C., Yu, L. S., Tungtrakarnkul, P., Wu, K. C., & Chuang, C. H. (2025). Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori. Analytical Chemistry, 97(45), 25148-25157. https://doi.org/10.1021/acs.analchem.5c04200

Vancouver

Kumar RR, Wang CY, Bharti AM, Hu WC, Zhang YC, Yu LS, et al. Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori. Analytical Chemistry. 2025;97(45):25148-25157. doi:10.1021/acs.analchem.5c04200

BibTeX
@article{Kumar2025,
  author = {Kumar, Rajkumar Rakesh and Wang, Chi-Yu and Bharti, Aditya Manu and Hu, Wen-Chian and Zhang, Yi-Chen and Yu, Ling-Shan and Tungtrakarnkul, Pornnapat and Wu, Kevin C-W and Chuang, Cheng-Hsin},
  title = {Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {45},
  pages = {25148--25157},
  doi = {10.1021/acs.analchem.5c04200}
}
Kostenlos starten →