Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori
Analytical Chemistry · 18.11.2025 · 97 (45) · 25148-25157
DOI: 10.1021/acs.analchem.5c04200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.11.2025. Verfasst von Rajkumar Rakesh Kumar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan. Hauptthemen laut MEDLINE: Helicobacter pylori, Graphite, Aniline Compounds, Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Helicobacter pylori (HP) infection is directly associated with over 90% of all gastric cancer (GC) cases. Currently available HP tests are prone to false negatives and are inapt for decentralization. Reliable and user-friendly detection platforms for timely diagnosis and routine monitoring are critical to patient survival. Herein, we targeted this unmet need by developing a novel biosensing platform that strategically combined the robust versatility of electrochemical techniques with the sensitivity and specificity of loop-mediated isothermal amplification (LAMP) to enable the accurate detection of HP at the point-of-care (POC). The biosensor design consisted of an underlying screen-printed carbon electrode (SCPE), sequentially modified with (i) highly conductive acid-functionalized sp2 graphene (Gr) and (ii) needle-like gold microstructures encapsulated with (iii) pH-sensitive polyaniline (PANI), assembled between laser-cut cover layers with a built-in reaction chamber for facile sample handling and detection. LAMP was performed using synthesized primers targeting the HP glmM gene. The amplification inherently generates H+, triggering pH variations, which are precisely tracked by the developed biosensor to simultaneously monitor amplicon growth and quantify HP DNA concentrations via two modes: continuous mode and segmented mode. High sensitivity in a wide linear range (1 to 107 copies/μL) with a limit of detection (LOD) of 1 copy/μL is reported. Furthermore, the excellent correlation with clinical results underscored the practical feasibility of this platform to allow reliable early diagnosis of HP infections and serve as a viable alternative to gastric endoscopy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
- Institute of Biomedical Engineering and Nanomedicine, National Heath Research Institutes, Miaoli 350401, Taiwan.
- Medical Cosmetic Institution, Kaohsiung Armed Forces General Hospital, Kaohsiung 802301, Taiwan.
- International PhD Program for Science, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
- Institute of Biopharmaceutical Science, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan.
- Department of Biomedical Engineering, Mahidol University, Nakhon Pathom 73170, Thailand.
ORCID-Profile: Rajkumar Rakesh Kumar, Aditya Manu Bharti, Ling-Shan Yu, Cheng-Hsin Chuang
Zitieren
APA
Kumar, R. R., Wang, C. Y., Bharti, A. M., Hu, W. C., Zhang, Y. C., Yu, L. S., Tungtrakarnkul, P., Wu, K. C., & Chuang, C. H. (2025). Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori. Analytical Chemistry, 97(45), 25148-25157. https://doi.org/10.1021/acs.analchem.5c04200
Vancouver
Kumar RR, Wang CY, Bharti AM, Hu WC, Zhang YC, Yu LS, et al. Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori. Analytical Chemistry. 2025;97(45):25148-25157. doi:10.1021/acs.analchem.5c04200
BibTeX
@article{Kumar2025,
author = {Kumar, Rajkumar Rakesh and Wang, Chi-Yu and Bharti, Aditya Manu and Hu, Wen-Chian and Zhang, Yi-Chen and Yu, Ling-Shan and Tungtrakarnkul, Pornnapat and Wu, Kevin C-W and Chuang, Cheng-Hsin},
title = {Hierarchical Graphene/Au/Polyaniline Nanostructured Electrode for Dual-Modality Electrochemical LAMP Biosensing of Helicobacter pylori},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {45},
pages = {25148--25157},
doi = {10.1021/acs.analchem.5c04200}
}