EUVIMEDObjevte EUVIMED
Crossref

Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS

Ronald V Emmons, William Fatigante, Aghogho A Olomukoro, Brian Musselman, Emanuela Gionfriddo iD

Journal of the American Society for Mass Spectrometry · 2023-09-06 · 34 (9) · 1890-1897

DOI: 10.1021/jasms.3c00088 ↗

At a glance

Journal article in Journal of the American Society for Mass Spectrometry, published online on 2023-06-01. Written by Ronald V Emmons and 4 co-authors. Institution: Department of Chemistry, The University of Toledo, Toledo, Ohio 43606, United States. Cited 38 times so far (Crossref); 40 references. Funded by: National Oceanic and Atmospheric Administration, ACS Division of Analytical Chemistry, National Science Foundation.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

Per- and polyfluoroalkyl substances (PFAS), an emerging class of toxic anthropogenic chemicals persistent in the environment, are currently regulated at the low part-per-trillion level worldwide in drinking water. Quantification and screening of these compounds currently rely primarily on liquid chromatography hyphenated to mass spectrometry (LC-MS). The growing need for quicker and more robust analysis in routine monitoring has been, in many ways, spearheaded by the advent of direct ambient mass spectrometry (AMS) technologies. Direct analysis in real time (DART), a plasma-based ambient ionization technique that permits rapid automated analysis, effectively ionizes a broad range of compounds, including PFAS. This work evaluates the performance of DART-MS for the screening and quantification of PFAS of different chemical classes, employing a central composite design (CCD) to better understand the interactions of DART parameters on their ionization. Furthermore, in-source fragmentation of the model PFAS was investigated based on the DART parameters evaluated. Preconcentration of PFAS from water samples was achieved by solid phase microextraction (SPME), and extracts were analyzed using the optimized DART-MS conditions, which allowed obtaining linear dynamic ranges (LDRs) within 10 and 5000 ng/L and LOQs of 10, 25, and 50 ng/L for all analytes. Instrumental analysis was achieved in less than 20 s per sample.

Authors and institutions

  • Department of Chemistry, The University of Toledo, Toledo, Ohio 43606, United States.
  • Dr. Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio 43606, United States.
  • Bruker Scientific LLC, Billerica, Massachusetts 01821, United States.
  • School of Green Chemistry and Engineering, The University of Toledo, Toledo, Ohio 43606, United States.

ORCID profiles: Emanuela Gionfriddo

Funding

  • National Oceanic and Atmospheric Administration
  • ACS Division of Analytical Chemistry
  • National Science Foundation

Cite

APA

Emmons, R. V., Fatigante, W., Olomukoro, A. A., Musselman, B., & Gionfriddo, E. (2023). Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS. Journal of the American Society for Mass Spectrometry, 34(9), 1890-1897. https://doi.org/10.1021/jasms.3c00088

Vancouver

Emmons RV, Fatigante W, Olomukoro AA, Musselman B, Gionfriddo E. Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS. Journal of the American Society for Mass Spectrometry. 2023;34(9):1890-1897. doi:10.1021/jasms.3c00088

BibTeX
@article{Emmons2023,
  author = {Emmons, Ronald V and Fatigante, William and Olomukoro, Aghogho A and Musselman, Brian and Gionfriddo, Emanuela},
  title = {Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS},
  journal = {Journal of the American Society for Mass Spectrometry},
  year = {2023},
  volume = {34},
  number = {9},
  pages = {1890--1897},
  doi = {10.1021/jasms.3c00088}
}
Start for free →