Perspective on SPME-MS: Green and high-performance methods for rapid screening
Analytica Chimica Acta · 2024-02 · 1291 · 342244
DOI: 10.1016/j.aca.2024.342244 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024-02. Verfasst von Wei Zhou und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 12 Literaturangaben. Gefördert von: World Anti-Doping Agency, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
The direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS) offers rapid analysis with high sensitivity and low matrix effects by benefiting from the integration of sampling, high enrichment, and clean-up functions of SPME. Eliminating chromatographic separation reduces the amount of gas/solvent needed for analysis, while direct desorption in SPME-MS consumes none or few microliters of organic solvents per sample, further enhancing the greenness of the SPME technology. Over the past two decades, the rapid evolution of SPME-MS has given rise to numerous novel technologies that employ diverse ionization techniques and interfaces, several of which have already been commercialized. Drawing from an extensive review published earlier this year and our research experience, we provide perspectives on three aspects of these technologies: interface design and automation, integration with state-of-art MS instrumentation, and anticipated future developments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
- Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada. Electronic address: janusz@uwaterloo.ca.
Förderung
- World Anti-Doping Agency
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Zhou, W., & Pawliszyn, J. (2024). Perspective on SPME-MS: Green and high-performance methods for rapid screening. Analytica Chimica Acta, 1291, 342244. https://doi.org/10.1016/j.aca.2024.342244
Vancouver
Zhou W, Pawliszyn J. Perspective on SPME-MS: Green and high-performance methods for rapid screening. Analytica Chimica Acta. 2024;1291:342244. doi:10.1016/j.aca.2024.342244
BibTeX
@article{Zhou2024,
author = {Zhou, Wei and Pawliszyn, Janusz},
title = {Perspective on SPME-MS: Green and high-performance methods for rapid screening},
journal = {Analytica Chimica Acta},
year = {2024},
volume = {1291},
pages = {342244},
doi = {10.1016/j.aca.2024.342244}
}
EUVIMED