EUVIMEDEUVIMED entdecken
Open Access

Implementation of SPME and rapid GC–MS as a screening approach for forensic fire debris applications

Briana A Capistran iD

Forensic Chemistry · 2024-05 · 38 · 100562

DOI: 10.1016/j.forc.2024.100562 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Forensic Chemistry, 2024-05. Verfasst von Briana A Capistran. Beteiligte Einrichtung: National Institute of Standards and Technology, Gaithersburg, MD, USA. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural NIST DOC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Analysis of ignitable liquids in fire debris samples can be a time-consuming process, from extraction of volatile compounds to instrumental analysis. Rapid gas chromatography-mass spectrometry (GC-MS) is a screening technique that can be utilized prior to confirmatory GC-MS analysis to provide an informative screening approach and possibly reduce the need to further analyze negative samples. Though rapid GC-MS is fast (less than two minutes), extraction techniques such as passive headspace extraction remain a bottleneck for decreasing overall workflow times. In this work, solid phase microextraction (SPME) was implemented with rapid GC-MS for ignitable liquid analysis for a faster, more sensitive screening approach compared to extraction with passive headspace. Using optimized inlet conditions, limits of detection as low as 27 ng/mL per compound were achieved. Gasoline and diesel fuel were extracted and analyzed, and major compounds in each liquid were identified in the resulting chromatograms. Extracted ion profiles (EIPs) and deconvolution methods were useful for additional compound identifications. Lastly, the SPME-rapid GC-MS workflow was extended to the analysis of gasoline and diesel fuel in mock burn samples using carpet and wood substrates. From SPME sample extraction to rapid GC-MS instrumental analysis and data processing, the total workflow for a single sample was reduced to under 20 min. These results indicate that SPME is a suitable injection technique for rapid GC-MS to provide a fast and sensitive screening approach for fire debris applications.

Schlagwörter

Stichwörter der Autor:innen

Forensic scienceIgnitable liquidsRapid GC-MSScreeningSolid phase microextraction

Autor:innen und Institutionen

  • National Institute of Standards and Technology, Gaithersburg, MD, USA.

ORCID-Profile: Briana A Capistran

Förderung

  • Intramural NIST DOC

Zitieren

APA

Capistran, B. A. (2024). Implementation of SPME and rapid GC–MS as a screening approach for forensic fire debris applications. Forensic Chemistry, 38, 100562. https://doi.org/10.1016/j.forc.2024.100562

Vancouver

Capistran BA. Implementation of SPME and rapid GC–MS as a screening approach for forensic fire debris applications. Forensic Chemistry. 2024;38:100562. doi:10.1016/j.forc.2024.100562

BibTeX
@article{Capistran2024,
  author = {Capistran, Briana A},
  title = {Implementation of SPME and rapid GC–MS as a screening approach for forensic fire debris applications},
  journal = {Forensic Chemistry},
  year = {2024},
  volume = {38},
  pages = {100562},
  doi = {10.1016/j.forc.2024.100562}
}
Kostenlos starten →