Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS
Journal of the American Society for Mass Spectrometry · 06.09.2023 · 34 (9) · 1890-1897
DOI: 10.1021/jasms.3c00088 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Society for Mass Spectrometry, online erschienen am 01.06.2023. Verfasst von Ronald V Emmons und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, The University of Toledo, Toledo, Ohio 43606, United States. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Oceanic and Atmospheric Administration, ACS Division of Analytical Chemistry, National Science Foundation.
Abstract (Originalsprache)
Per- and polyfluoroalkyl substances (PFAS), an emerging class of toxic anthropogenic chemicals persistent in the environment, are currently regulated at the low part-per-trillion level worldwide in drinking water. Quantification and screening of these compounds currently rely primarily on liquid chromatography hyphenated to mass spectrometry (LC-MS). The growing need for quicker and more robust analysis in routine monitoring has been, in many ways, spearheaded by the advent of direct ambient mass spectrometry (AMS) technologies. Direct analysis in real time (DART), a plasma-based ambient ionization technique that permits rapid automated analysis, effectively ionizes a broad range of compounds, including PFAS. This work evaluates the performance of DART-MS for the screening and quantification of PFAS of different chemical classes, employing a central composite design (CCD) to better understand the interactions of DART parameters on their ionization. Furthermore, in-source fragmentation of the model PFAS was investigated based on the DART parameters evaluated. Preconcentration of PFAS from water samples was achieved by solid phase microextraction (SPME), and extracts were analyzed using the optimized DART-MS conditions, which allowed obtaining linear dynamic ranges (LDRs) within 10 and 5000 ng/L and LOQs of 10, 25, and 50 ng/L for all analytes. Instrumental analysis was achieved in less than 20 s per sample.
Autor:innen und Institutionen
- Department of Chemistry, The University of Toledo, Toledo, Ohio 43606, United States.
- Dr. Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio 43606, United States.
- Bruker Scientific LLC, Billerica, Massachusetts 01821, United States.
- School of Green Chemistry and Engineering, The University of Toledo, Toledo, Ohio 43606, United States.
ORCID-Profile: Emanuela Gionfriddo
Förderung
- National Oceanic and Atmospheric Administration
- ACS Division of Analytical Chemistry
- National Science Foundation
Zitieren
APA
Emmons, R. V., Fatigante, W., Olomukoro, A. A., Musselman, B., & Gionfriddo, E. (2023). Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS. Journal of the American Society for Mass Spectrometry, 34(9), 1890-1897. https://doi.org/10.1021/jasms.3c00088
Vancouver
Emmons RV, Fatigante W, Olomukoro AA, Musselman B, Gionfriddo E. Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS. Journal of the American Society for Mass Spectrometry. 2023;34(9):1890-1897. doi:10.1021/jasms.3c00088
BibTeX
@article{Emmons2023,
author = {Emmons, Ronald V and Fatigante, William and Olomukoro, Aghogho A and Musselman, Brian and Gionfriddo, Emanuela},
title = {Rapid Screening and Quantification of PFAS Enabled by SPME-DART-MS},
journal = {Journal of the American Society for Mass Spectrometry},
year = {2023},
volume = {34},
number = {9},
pages = {1890--1897},
doi = {10.1021/jasms.3c00088}
}
EUVIMED