EUVIMEDObjevte EUVIMED
Crossref

WSe 2 Negative Capacitance Field-Effect Transistor for Biosensing Applications

Xian Wu, Sen Gao, Lei Xiao, Jing Wang iD

ACS Applied Materials & Interfaces · 2024-08-14 · 16 (32) · 42597-42607

DOI: 10.1021/acsami.4c06648 ↗

At a glance

Journal article in ACS Applied Materials & Interfaces, published online on 2024-08-05. Written by Xian Wu and 3 co-authors. Institution: School of Integrated Circuits, Tsinghua University, Beijing 100084, China. Major MEDLINE topics: Biosensing Techniques, Transistors, Electronic, Electric Capacitance, Glucose. Cited 15 times so far (Crossref); 63 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Field-effect transistor (FET) biosensors based on two-dimensional (2D) materials are highly sought after for their high sensitivity, label-free detection, fast response, and ease of on-chip integration. However, the subthreshold swing (SS) of FETs is constrained by the Boltzmann limit and cannot fall below 60 mV/dec, hindering sensor sensitivity enhancement. Additionally, the gate-leakage current of 2D material biosensors in liquid environments significantly increases, adversely affecting the detection accuracy and stability. Based on the principle of negative capacitance, this paper presents for the first time a two-dimensional material WSe2 negative capacitance field-effect transistor (NCFET) with a minimum subthreshold swing of 56 mV/dec in aqueous solution. The NCFET shows a significantly improved biosensor function. The pH detection sensitivity of the NCFET biosensor reaches 994 pH-1, nearly an order of magnitude higher than that of the traditional two-dimensional WSe2 FET biosensor. The Al2O3/HfZrO (HZO) bilayer dielectric in the NCFET not only contributes to negative capacitance characteristics in solution but also significantly reduces the leakage in solution. Utilizing an enzyme catalysis method, the WSe2 NCFET biosensor demonstrates a specific detection of glucose molecules, achieving a high sensitivity of 4800 A/A in a 5 mM glucose solution and a low detection limit (10-9 M). Further experiments also exhibit the ability of the biosensor to detect glucose in sweat.

Subjects

MeSH terms (MEDLINE)

Biosensing TechniquesTransistors, ElectronicElectric CapacitanceGlucoseAluminum OxideHafniumHydrogen-Ion ConcentrationOxides

Author keywords

WSe2glucose sensingnegative capacitance field-effect transistorpH sensingsensitivitysubthreshold swing

Substances

GlucoseAluminum OxideHafniumhafnium oxideOxides

Authors and institutions

  • School of Integrated Circuits, Tsinghua University, Beijing 100084, China.

ORCID profiles: Jing Wang

Cite

APA

Wu, X., Gao, S., Xiao, L., & Wang, J. (2024). WSe 2 Negative Capacitance Field-Effect Transistor for Biosensing Applications. ACS Applied Materials & Interfaces, 16(32), 42597-42607. https://doi.org/10.1021/acsami.4c06648

Vancouver

Wu X, Gao S, Xiao L, Wang J. WSe 2 Negative Capacitance Field-Effect Transistor for Biosensing Applications. ACS Applied Materials & Interfaces. 2024;16(32):42597-42607. doi:10.1021/acsami.4c06648

BibTeX
@article{Wu2024,
  author = {Wu, Xian and Gao, Sen and Xiao, Lei and Wang, Jing},
  title = {WSe 2 Negative Capacitance Field-Effect Transistor for Biosensing Applications},
  journal = {ACS Applied Materials & Interfaces},
  year = {2024},
  volume = {16},
  number = {32},
  pages = {42597--42607},
  doi = {10.1021/acsami.4c06648}
}
Start for free →