Evaluationsstudie in der Zeitschrift Enzyme and Microbial Technology, 2024. Verfasst von Alessandra Teixeira Felix und 2 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Química e Biotecnologia e Engenharia de Bioprocessos, CAP-UFSJ, Rod. MG 443, Km 07, Ouro Branco, MG 36497-899, Brazil. Hauptthemen laut MEDLINE: Biosensing Techniques, Enzymes, Immobilized, Glucose Oxidase, Glucose. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
The sensing modified electrode was prepared using glucose oxidase immobilized onto vanadium pentoxide xerogel with glass/FTO as support electrode to evaluate the possibility to construct a V2O5/GOx Extended Gate Field Effect Transistor biosensor. Previously, our studies exhibited a sensitivity of V2O5 of 58.1 mV/pH. The use of Nafion® onto V2O5/GOx caused a decrease of mass loss after several cycles compared to the modified electrode without Nafion® during the EQCM and cyclic voltammetrics studies. Electrical characterization of V2O5/GOx demonstrated a tendency to stability after 200 s as a function of applied current. In presence of glucose and in different pH, the current decreased when the glucose concentration increased due to the lower active sites of enzyme. After ten voltammetric cycles, the total charge tends to structural stability. In pH = 5.0, the modified electrode based on V2O5/GOx Extended Gate Field Effect Transistor presented more tendency to sensitivity in different concentration of glucose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Departamento de Química e Biotecnologia e Engenharia de Bioprocessos, CAP-UFSJ, Rod. MG 443, Km 07, Ouro Branco, MG 36497-899, Brazil.
- Departamento de Física, FFCLRP-USP, Av. Bandeirantes, 3900, Ribeirão Preto, SP 14040-901, Brazil.
- Departamento de Química e Biotecnologia e Engenharia de Bioprocessos, CAP-UFSJ, Rod. MG 443, Km 07, Ouro Branco, MG 36497-899, Brazil. Electronic address: elidiaguerra@ufsj.edu.br.
Zitieren
APA
Felix, A. T., Mulato, M., & Guerra, E. M. (2024). Evaluation of sensitivity of Extended Gate Field Effect Transistor -biosensor based on V2O5/GOx for glucose detection. Enzyme and Microbial Technology. https://doi.org/10.1016/j.enzmictec.2024.110428
Vancouver
Felix AT, Mulato M, Guerra EM. Evaluation of sensitivity of Extended Gate Field Effect Transistor -biosensor based on V2O5/GOx for glucose detection. Enzyme and Microbial Technology. 2024. doi:10.1016/j.enzmictec.2024.110428
BibTeX
@article{Felix2024,
author = {Felix, Alessandra Teixeira and Mulato, Marcelo and Guerra, Elidia Maria},
title = {Evaluation of sensitivity of Extended Gate Field Effect Transistor -biosensor based on V2O5/GOx for glucose detection},
journal = {Enzyme and Microbial Technology},
year = {2024},
doi = {10.1016/j.enzmictec.2024.110428}
}
EUVIMED