Vergleichsstudie in der Zeitschrift Translational Vision Science & Technology, erschienen am 19.08.2025. Verfasst von Shalinder Sabherwal und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Community Ophthalmology and Public Health Research, Dr. Shroff's Charity Eye Hospital, New Delhi, India. Hauptthemen laut MEDLINE: Visual Acuity, Vision Screening, Vision Tests, Vision Disorders. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The Peek digital near vision test has been previously validated in a trial setting; here it is assessed in clinic (stage 1) and community (stage 2) settings.

Methods

The study was carried out in the catchment area of Dr. Shroff's Charity Eye Hospital, Mohammadi, Uttar Pradesh, India, with a total of 768 participants. Stage 1 assessed the interobserver variability of Peek near vision impairment (NVI) screening in 168 clinic participants, with three trained community screeners. Stage 2 compared Peek to conventional chart testing for NVI screening using Cohen's kappa coefficient, sensitivity, and specificity and, for quantitative near visual acuity (NVA) measurement, using Bland-Altman limits of agreement (LoA) in 600 participants with two screeners.

Results

In stage 1, interobserver variability using Peek ranged from 96.43% to 98.21% (kappa = 0.92-0.96). In stage 2, there was overall agreement in 95.8% of cases (kappa = 0.91). Peek testing had a sensitivity and specificity of 91.25% (95% confidence interval [CI], 87.22-94.1) and 99.41% (95% CI, 97.86-99.84), respectively. For NVA testing, the 95% LoA between Peek and chart testing were within -0.11 and +0.07 logMAR. Mean test time was 40.3 seconds (95% CI, 38.8-41.7) for Peek versus 46.6 seconds (95% CI, 45.5-47.7) for a conventional chart.

Conclusions

The previously demonstrated validity of Peek testing was maintained when used by trained community screeners. Translational Relevance: The Peek near vision test can be used as a validated method of NVA/NVI measurement in research, clinical and community settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityVision ScreeningVision TestsVision DisordersHumansIndiaFemaleMaleAdultMiddle AgedObserver VariationYoung AdultSensitivity and SpecificityReproducibility of ResultsAgedAdolescent

Autor:innen und Institutionen

  • Department of Community Ophthalmology and Public Health Research, Dr. Shroff's Charity Eye Hospital, New Delhi, India.
  • International Centre for Eye Health, London School of Hygiene and Tropical Medicine, London, UK.
  • Dr. Shroff's Charity Eye Hospital, New Delhi, India.
  • Peek Vision, Berkhamsted, UK.
  • Tennent Institute of Ophthalmology, Glasgow, UK.
  • Department of Ophthalmology, Rigshospitalet, Copenhagen University Hospital, Glostrup, Denmark.

Förderung

  • Wellcome Trust

Zitieren

APA

Sabherwal, S., Javed, M., Watts, E., Katibeh, M., Pintus, A., Thaker, N., Latorre-Arteaga, S., Hewitt, V., Coverley, D., Bolster, N. M., & Bastawrous, A. (2025). Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India. Translational Vision Science & Technology, 14(8), 24. https://doi.org/10.1167/tvst.14.8.24

Vancouver

Sabherwal S, Javed M, Watts E, Katibeh M, Pintus A, Thaker N, et al. Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India. Translational Vision Science & Technology. 2025;14(8):24. doi:10.1167/tvst.14.8.24

BibTeX
@article{Sabherwal2025,
  author = {Sabherwal, Shalinder and Javed, Mohd and Watts, Elanor and Katibeh, Marzieh and Pintus, Alice and Thaker, Nam and Latorre-Arteaga, Sergio and Hewitt, Vince and Coverley, Darren and Bolster, Nigel M and Bastawrous, Andrew},
  title = {Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  volume = {14},
  number = {8},
  pages = {24},
  doi = {10.1167/tvst.14.8.24}
}
Kostenlos starten →