A prospective study of bladder volume assessment using ultrasound in prostate cancer radiotherapy: Comparison with cone-beam computed tomography (CBCT)
Radiography · 2025
DOI: 10.1016/j.radi.2025.103016 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiography, 2025. Verfasst von B Bąk und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electroradiology, University of Medical Sciences, Poznań, Poland; Radiotherapy Department II, Greater Poland Cancer Center, Poznań, Pol…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Prostatic Neoplasms, Urinary Bladder. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Centrum fÖr Personcentrerad Vård.
Abstract (Originalsprache)
INTRODUCTION: Prostate cancer radiotherapy requires consistent bladder filling to optimize dose delivery and minimize toxicity. This prospective study evaluated the accuracy of ultrasound (US) in bladder volume assessment compared to Cone Beam Computed Tomography (CBCT). METHODS: 22 prostate cancer patients treated with a total dose of 50 Gy in 2 Gy fractions (25 fractions) between August and December 2019 using volumetric arc therapy (VMAT). Prior to initial CT (iCT) scans and during radiotherapy patients consumed 600-800 ml (3-4 cups) of water. Daily ultrasound measurements were taken to determine the mean bladder volume (USGRT) before Cone Beam Computed Tomography (CBCT) imaging, where the radiation therapist contoured the bladder on CBCT scans, calculating bladder volume with a 2 mm margin. RESULTS: A total of 1650 ultrasound measurements were performed. Statistical analysis included the Wilcoxon rank test and Spearman correlation to compare bladder volumes. The mean bladder volume measured by the US was 286 ml (SD ± 118), while CBCT recorded 241 ml (SD ± 124), with a strong correlation (r = 0.888, p < 0.001). The coefficient between USGRT and V2CBCT was r = 0.84 (p < 0.0001), indicating a significant correlation. CONCLUSION: The Echoson® bladder scanner showed potential as a non-invasive alternative for daily bladder volume monitoring, reducing radiation exposure and streamlining treatment workflows. The bladder filling protocol is suitable for all patients, with a clinically acceptable measurement error of 17 %. IMPLICATIONS FOR PRACTICE: Ultrasound enhances daily IGRT verification while minimizing radiation dose from CBCT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electroradiology, University of Medical Sciences, Poznań, Poland; Radiotherapy Department II, Greater Poland Cancer Center, Poznań, Poland. Electronic address: bartosz.bak@wco.pl.
- Department of Electroradiology, University of Medical Sciences, Poznań, Poland. Electronic address: krzysztof.kaczmarek@wco.pl.
- Department of Electroradiology, University of Medical Sciences, Poznań, Poland; Radiotherapy Department II, Greater Poland Cancer Center, Poznań, Poland. Electronic address: dariusz.radola@wco.pl.
- Radiotherapy Ward II, Greater Poland Cancer Center, Poznań, Poland. Electronic address: tomasz.winiecki@wco.pl.
- Radiotherapy Ward II, Greater Poland Cancer Center, Poznań, Poland. Electronic address: tomasz.bajon@wco.pl.
Förderung
- Centrum fÖr Personcentrerad Vård
Zitieren
APA
Bąk, B., Kaczmarek, K., Radoła, D., Winiecki, T., & Bajon, T. (2025). A prospective study of bladder volume assessment using ultrasound in prostate cancer radiotherapy: Comparison with cone-beam computed tomography (CBCT). Radiography. https://doi.org/10.1016/j.radi.2025.103016
Vancouver
Bąk B, Kaczmarek K, Radoła D, Winiecki T, Bajon T. A prospective study of bladder volume assessment using ultrasound in prostate cancer radiotherapy: Comparison with cone-beam computed tomography (CBCT). Radiography. 2025. doi:10.1016/j.radi.2025.103016
BibTeX
@article{Bk2025,
author = {Bąk, B and Kaczmarek, K and Radoła, D and Winiecki, T and Bajon, T},
title = {A prospective study of bladder volume assessment using ultrasound in prostate cancer radiotherapy: Comparison with cone-beam computed tomography (CBCT)},
journal = {Radiography},
year = {2025},
doi = {10.1016/j.radi.2025.103016}
}
EUVIMED