EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The effect of interfractional variation on delivered dose with ultrahypofractionated pencil beam scanning proton therapy for localized prostate cancer

Keyur D Shah iD, Duncan H Bohannon, Sagar A Patel, Chih-Wei Chang, Vishal R Dhere, Yinan Wang, Anees Dhabaan iD, Hania Al-Hallaq, Xiaofeng Yang iD, Jun Zhou iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Keyur D Shah und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Proton Therapy, Organs at Risk. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose/objectives Proton stereotactic body radiotherapy (SBRT) using the pencil beam scanning (PBS) technique is increasingly used for localized prostate cancer (PCa) due to its potential for superior normal tissue sparing. However, interfractional anatomical variations pose challenges for accurate dose delivery, especially in ultrahypofractionation. This study investigates the dosimetric impact of these variations in PCa patients treated with PBS‐SBRT.

Methods

Forty‐two low‐ or intermediate‐risk PCa patients treated with PBS‐SBRT (36.25/ 40 Gy in 5 fractions) were included. Delivered doses were calculated by applying the initial plans to HU and artifact‐corrected pre‐treatment cone‐beam computed tomography (CBCT) images. Dosimetric parameters were evaluated per fraction. Key anatomical features included clinical target volume (CTV) shifts in the superior‐inferior (SI) and anterior‐posterior (AP) directions, and volume changes in the bladder and rectum. These features were used to predict deviations in CTV D 99 and D 0.03cc , as well as maximum bladder and rectum doses. Univariate and multivariate logistic regression models were developed to identify significant anatomical predictors of dosimetric deviations, with odds ratios (OR) and area under the curve (AUC) values reported for predictive performance evaluation.

Results

CTV AP shifts and bladder/rectum volume changes were significant predictors of dosimetric deviations. Univariate analyses indicated that bladder volume increases > 109.80 cc were strongly associated with deviations in CTV D 0.03cc (mean deviation = 0.33 Gy, OR = 5.78, p = 0.03). Rectum volume changes > 9.22 cc were the strongest predictor of rectum D 0.03cc deviations (mean deviation = 0.68 Gy, OR = 4.23, p = 0.01). AP shifts > −0.27 cm were also predictive of CTV D 0.03cc deviations (OR = 0.35, p = 0.01). Multivariate model predicting rectum D 0.03cc achieved the highest AUC (0.73), followed by CTV D 0.03cc (AUC = 0.68).

Conclusion

Multivariate models incorporating bladder volume changes and CTV shifts accurately predict dosimetric deviations in PBS‐SBRT. These findings highlight the need for adaptive strategies during PBS‐SBRT to mitigate the impact of interfractional variations, optimize dose delivery precision, and reduce toxicity in high‐risk patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsRadiotherapy Planning, Computer-AssistedProton TherapyOrgans at RiskRadiosurgeryHumansMaleRadiotherapy DosageCone-Beam Computed TomographyRadiotherapy, Intensity-ModulatedAgedRetrospective StudiesMiddle AgedUrinary Bladder

Stichwörter der Autor:innen

interfraction variationprostate cancerproton therapy

Autor:innen und Institutionen

  • Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.

ORCID-Profile: Keyur D Shah, Anees Dhabaan, Xiaofeng Yang, Jun Zhou

Zitieren

APA

Shah, K. D., Bohannon, D. H., Patel, S. A., Chang, C. W., Dhere, V. R., Wang, Y., Dhabaan, A., Al-Hallaq, H., Yang, X., & Zhou, J. (2025). The effect of interfractional variation on delivered dose with ultrahypofractionated pencil beam scanning proton therapy for localized prostate cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70223

Vancouver

Shah KD, Bohannon DH, Patel SA, Chang CW, Dhere VR, Wang Y, et al. The effect of interfractional variation on delivered dose with ultrahypofractionated pencil beam scanning proton therapy for localized prostate cancer. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70223

BibTeX
@article{Shah2025,
  author = {Shah, Keyur D and Bohannon, Duncan H and Patel, Sagar A and Chang, Chih-Wei and Dhere, Vishal R and Wang, Yinan and Dhabaan, Anees and Al-Hallaq, Hania and Yang, Xiaofeng and Zhou, Jun},
  title = {The effect of interfractional variation on delivered dose with ultrahypofractionated pencil beam scanning proton therapy for localized prostate cancer},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70223}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche