Fachartikel in der Zeitschrift BioMed Research International, 2024. Verfasst von Hao Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology First Affiliated Hospital of Soochow University, Suzhou 215000, China. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Cone-Beam Computed Tomography, Urinary Bladder. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The precision of postoperative prostate cancer radiotherapy is significantly influenced by setup errors and alterations in bladder morphology. Utilizing daily cone beam computed tomography (CBCT) imaging allows for the correction of setup errors. However, this naturally leads to the question of the issue of peripheral dose and workload. Thus, a zero‐dose, noninvasive technique to reproduce the bladder volume and improve patient setup accuracy was needed.
Purpose
The aim of this study is to investigate if the setup method by combining Optical Surface Management System (OSMS) and BladderScan can improve the accuracy of setup and accurately reproduce the bladder volume during radiotherapy of postoperative prostate cancer and to guide CTV‐PTV margins for clinic.
Method
The experimental group consisted of 15 postoperative prostate cancer patients who utilized a setup method that combined OSMS and BladderScan. This group recorded 103 setup errors, verified by CBCT. The control group comprised 25 patients, among whom 114 setup errors were recorded using the conventional setup method involving skin markers; additionally, patients in this group also exhibited spontaneous urinary suppression. The errors including lateral (Lat), longitudinal (Lng), vertical directions (Vrt), Pitch, Yaw, and Roll were analyzed between the two methods. The Dice similarity coefficient (DSC) and volume differences of the bladder between CBCT and planning CT were compared as the bladder concordance indicators.
Results
The errors in the experimental group at Vrt, Lat, and Lng were 0.17 ± 0.12, 0.22 ± 0.17, and 0.18 ± 0.12 cm, and the control group were 0.25 ± 0.15, 0.31 ± 0.21, 0.34 ± 0.22 cm. The rotation errors of Pitch, Roll, and Yaw in the experimental group were 0.18 ± 0.12°, 0.11 ± 0.1°, and 0.18 ± 0.13°, and in the control group, they were 0.96 ± 0.89°, 1.01 ± 0.86°, and 1.02 ± 0.84°. The DSC and volume differences were 92.52 ± 1.65 % and 39.99 ± 28.75 cm 3 in the patients with BladderScan, and in the control group, they were 62.98 ± 22.33 % , 273.89 ± 190.62 cm 3 . The P < 0.01 of the above performance indicators indicates that the difference is statistically significant.
Conclusion
The accuracy of the setup method by combining OSMS and BladderScan was validated by CBCT in our study. The method in our study can improve the setup accuracy during radiotherapy of postoperative prostate cancer compared to the conventional setup method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology First Affiliated Hospital of Soochow University, Suzhou 215000, China.
ORCID-Profile: Songbin Qin, Guanghui Gan
Zitieren
APA
Chen, H., Liu, Y., Qin, S., & Gan, G. (2024). Optical Surface Management System and BladderScan for Patient Setup During Radiotherapy of Postoperative Prostate Cancer. BioMed Research International. https://doi.org/10.1155/2024/3573796
Vancouver
Chen H, Liu Y, Qin S, Gan G. Optical Surface Management System and BladderScan for Patient Setup During Radiotherapy of Postoperative Prostate Cancer. BioMed Research International. 2024. doi:10.1155/2024/3573796
BibTeX
@article{Chen2024,
author = {Chen, Hao and Liu, Yandong and Qin, Songbin and Gan, Guanghui},
title = {Optical Surface Management System and BladderScan for Patient Setup During Radiotherapy of Postoperative Prostate Cancer},
journal = {BioMed Research International},
year = {2024},
doi = {10.1155/2024/3573796}
}
EUVIMED