Does adding markers increase the accuracy and efficiency of intraoral scanning of complete dentures?
The Journal of Prosthetic Dentistry · 2026-04 · 135 (4) · 809-817
DOI: 10.1016/j.prosdent.2025.05.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-04. Verfasst von Jiayi Lu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Fellow, Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich. Hauptthemen laut MEDLINE: Denture, Complete, Denture Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: School of Dentistry, University of Michigan.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Scanning a complete denture with an intraoral scanner has become an integral part of contemporary dental workflows, particularly for a digitally fabricated denture. However, whether the efficiency and accuracy of denture scanning can be improved by adding markers is unclear. PURPOSE: The purpose of this study was to evaluate a new workflow and investigate whether it could optimize the efficiency and accuracy of a denture scan using an intraoral scanner. MATERIAL AND METHODS: Two groups of denture scans were generated from a standard maxillary complete denture for comparison. In Group NM (no markers), the denture was scanned 20 times with an intraoral scanner using a consistent scan strategy. In Group WM (with markers), polyvinyl siloxane markers were added onto the denture as scan-aids, followed by 20 scans using the same scan strategy. A reference scan was obtained by using a desktop scanner (D2000). Test scans were aligned to the reference model using a best-fit algorithm in the exocad software program, excluding the cameo surface. The intaglio surface and 1 mm beyond the denture border were cropped and saved as a combined surface. This surface was further segmented into 4 critical regions: the denture border, posterior palatal seal zone, ridge area, and palatal area. Root mean square (RMS) values were calculated for the combined surface and segmented areas to assess accuracy. Scanning time, failure rate, and the number of 3-dimensional (3D) images were also recorded. Statistical analysis was performed using the Mann-Whitney U test and Levene test to compare trueness, scanning time, and the number of 3D images between the 2 groups (α=.05). Color mapping was used to visualize the surface deviations. RESULTS: Group WM demonstrated significantly better trueness and precision than Group NM across all evaluated regions. The mean RMS deviation for the combined surface was 37.6 µm in Group WM compared with 47.1 µm in Group NM (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research Fellow, Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
- Clinical Professor, Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich.
- Clinical Assistant Professor, Department of Biologic and Materials Sciences and Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Mich. Electronic address: junying@umich.edu.
Förderung
- School of Dentistry, University of Michigan
Zitieren
APA
Lu, J., Yu, J., Saglik, B., & Li, J. (2026). Does adding markers increase the accuracy and efficiency of intraoral scanning of complete dentures?. The Journal of Prosthetic Dentistry, 135(4), 809-817. https://doi.org/10.1016/j.prosdent.2025.05.016
Vancouver
Lu J, Yu J, Saglik B, Li J. Does adding markers increase the accuracy and efficiency of intraoral scanning of complete dentures?. The Journal of Prosthetic Dentistry. 2026;135(4):809-817. doi:10.1016/j.prosdent.2025.05.016
BibTeX
@article{Lu2026,
author = {Lu, Jiayi and Yu, Jiayi and Saglik, Berna and Li, Junying},
title = {Does adding markers increase the accuracy and efficiency of intraoral scanning of complete dentures?},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {135},
number = {4},
pages = {809--817},
doi = {10.1016/j.prosdent.2025.05.016}
}
EUVIMED