Vergleichsstudie

Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core

Xinyue Cui iD, Yushu Liu iD, Rui Zhang, Xinzhi Wang iD

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.13974 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Xinyue Cui und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Beijing Jishuitan Hospital, Capital Medical University, Beijing, PR China. Hauptthemen laut MEDLINE: Siloxanes, Polyvinyls, Dental Impression Technique, Computer-Aided Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Science and Technology Innovation Commission of Shenzhen, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This in vitro study aimed to compare the 3‐dimensional (3D) accuracy of intraoral and desktop scanners when digitizing the post and core polyvinyl siloxane impressions. Material and Methods Ten extracted human teeth were prepared to build a post space in the root canal. Each tooth was scanned using a micro‐computed tomography device (MCT), and the slice data were reconstructed as controls. A conventional quadrant polyvinyl siloxane impression was made and scanned thrice using an intraoral scanner (IOS) and a desktop blue‐light scanner (IMS), with one of the scans randomly selected as the definitive cast. Precision was assessed by comparing the deviations among repeated scans. Trueness was evaluated by analyzing the deviations between the MCT and each definitive cast (MCT‐IOS and MCT‐IMS). The clinically acceptable root mean square (RMS) value was set to 50 µm.

Results

The mean RMS values of the repeated scans of IOS and IMS were 18.3 ± 3.9 µm and 13.9 ± 6.2 µm ( P < 0.05), and the difference between them was 4.4 ± 5.9 µm. The mean RMS values of MCT‐IOS and MCT‐IMS were 28.3 ±3.0 µm and 31.3 ± 4.2 µm ( P < 0.05), with a difference of 3.0 ± 2.9 µm. The RMS values were significantly lower than 50 µm ( P < 0.05).

Conclusions

The IOS showed slightly better trueness than the IMS but slightly lower precision. The precision and trueness of the two scanners for digitizing post and core impressions were acceptable for clinical application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SiloxanesPolyvinylsDental Impression TechniqueComputer-Aided DesignDental Impression MaterialsDental Prosthesis DesignHumansX-Ray MicrotomographyIn Vitro TechniquesImaging, Three-Dimensional

Stichwörter der Autor:innen

CAD‐CAMaccuracydigitizingmicro‐computed tomographypost and core

Substanzen

SiloxanesPolyvinylsvinyl polysiloxaneDental Impression Materials

Autor:innen und Institutionen

  • Department of Dentistry, Beijing Jishuitan Hospital, Capital Medical University, Beijing, PR China.
  • Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, PR China.
  • Department of Prosthodontics, Stomatology Center, Peking University Shenzhen Hospital, Shenzhen, PR China.
  • Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.

ORCID-Profile: Xinyue Cui, Yushu Liu, Xinzhi Wang

Förderung

  • Science and Technology Innovation Commission of Shenzhen, China

Zitieren

APA

Cui, X., Liu, Y., Zhang, R., & Wang, X. (2025). Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13974

Vancouver

Cui X, Liu Y, Zhang R, Wang X. Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13974

BibTeX
@article{Cui2025,
  author = {Cui, Xinyue and Liu, Yushu and Zhang, Rui and Wang, Xinzhi},
  title = {Accuracy of intraoral versus desktop scanners used in digitizing polyvinyl siloxane impression for fabricating a CAD‐CAM customized post and core},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.13974}
}
Kostenlos starten →