EUVIMEDEUVIMED entdecken
Vergleichsstudie

Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records

Elena Kan iD, Dianne Luu, Soo-Woo Kim, Richard Liu, Jason D Lee iD, Sang J Lee iD

Journal of Prosthodontics · 2024

DOI: 10.1111/jopr.13896 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Elena Kan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Dental Impression Technique, Models, Dental, Computer-Aided Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Greater New York of Academy of Prosthodontics (GNYAP).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the accuracy of a partially digital cross‐mounting workflow of direct scans of interocclusal records to a conventional workflow by analyzing the deviations of sequentially cross‐mounted casts. Materials and methods A set of reference casts, comprising maxillary and mandibular full‐arch prepared casts and interim prostheses, was articulated, mounted, and scanned to generate four reference casts for cross‐mounting. In the conventional approach, 15 sets of these four casts were printed. Polyvinylsiloxane (PVS) records were made using the reference casts and utilized for sequential cross‐mounting. In the partially digital group, the same PVS interocclusal records were scanned and used for digital cross‐mounting via design software. The mean deviations of both groups from the reference cast were analyzed using a 3D inspection software program. Statistical tests, including paired t ‐test and analysis of variance (ANOVA), were conducted to compare the average discrepancies between the two groups and to evaluate discrepancies in the anterior and posterior regions (α = 0.05).

Results

The range of discrepancies was similar in both the conventional and partially digital groups. The final set of related casts had a mean deviation of 201.58 ± 136.98 mm in the conventional workflow and 248.69 ± 164.71 mm in the partially digital workflow. No statistically significant difference was found between conventional and partially digital groups ( p = 0.091). Error propagation was examined by comparing discrepancies at each step within the cross‐mounting process. In the conventional group, no significant difference was found ( p = 0.148), but a significant difference was found among groups in the partially digital group at each step of sequential mounting ( p < 0.001). A significant difference was observed between anterior and posterior deviations in the partially digital group ( p < 0.001), but not in the conventional group ( p = 0.143).

Conclusions

The study reveals that there is no statistically significant difference between conventional and partially digital cross‐mounting workflows. However, within the partially digital group, a significant difference in deviation emerges across cross‐mounting steps, with increased deviation in the anterior region.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Impression TechniqueModels, DentalComputer-Aided DesignHumansJaw Relation RecordPolyvinylsWorkflowSoftwareSiloxanesImaging, Three-Dimensional

Stichwörter der Autor:innen

accuracyarticulationcross‐mountingdigital scan

Substanzen

Polyvinylsvinyl polysiloxaneSiloxanes

Autor:innen und Institutionen

  • Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
  • Department of Oral Medicine, Infection and Immunity Harvard School of Dental Medicine, Boston, Massachusetts, USA.

ORCID-Profile: Elena Kan, Jason D Lee, Sang J Lee

Förderung

  • Greater New York of Academy of Prosthodontics (GNYAP)

Zitieren

APA

Kan, E., Luu, D., Kim, S. W., Liu, R., Lee, J. D., & Lee, S. J. (2024). Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13896

Vancouver

Kan E, Luu D, Kim SW, Liu R, Lee JD, Lee SJ. Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13896

BibTeX
@article{Kan2024,
  author = {Kan, Elena and Luu, Dianne and Kim, Soo-Woo and Liu, Richard and Lee, Jason D and Lee, Sang J},
  title = {Analyzing the accuracy of a cross‐mounting technique utilizing digitized interocclusal records},
  journal = {Journal of Prosthodontics},
  year = {2024},
  doi = {10.1111/jopr.13896}
}
Kostenlos starten →