Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication
Journal of Dentistry · 2026
DOI: 10.1016/j.jdent.2026.106571 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Dentistry, 2026. Verfasst von Gülce Çakmak und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Universitätsmedizin Berlin, Corporate Member of Freie Unive…. Hauptthemen laut MEDLINE: Models, Dental, Computer-Aided Design, Denture, Partial, Removable, Denture Design. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVES: To evaluate the surface and positional trueness of removable dies fabricated using fused filament fabrication (FFF), compared to dies produced with digital light processing (DLP), addressing the limited evidence on the deviations of FFF-based removable dies. METHODS: A typodont with a prepared right mandibular first molar was digitized to design a removable die and corresponding hollow partial arch cast. Forty dies (n = 10) and four casts (n = 1) were fabricated using FFF (Filadent Aligner [FF-AL], Filadent Gypsum [FF-GP], Filadent Tray [FF-TR]) or DLP (DentaModel [DM]). Dies and their positions in the casts were digitized to assess surface (crown, root, root base, overall) and positional (crown region and point-based) deviations. Data were analyzed either with one-way analysis of variance (surface deviations) or Kruskal-Wallis tests (positional deviations, α = 0.05). RESULTS: DM exhibited the lowest crown region and overall deviations, followed by FF-TR (P < 0.001). Root deviations increased in the order of DM, FF-TR, FF-AL, and FF-GP, whereas FF-TR had the lowest base of the root deviations (P < 0.001). Seated FF-GP dies had lower crown region deviations than the other FFF-based dies, while DM led to lower deviations than FF-TR (P ≤ 0.041). FF-AL showed lower point-based deviations than FF-GP (P = 0.001). CONCLUSIONS: FFF-fabricated dies showed lower surface trueness than DM dies, with FF-TR achieving the highest trueness among FFF dies. Positional deviations remained within clinically acceptable limits, though FF-TR dies tended to be positioned coronally and the others apically. FFF may be used to produce clinically acceptable dies, but DLP offers superior surface trueness. CLINICAL SIGNIFICANCE: Removable dies produced with the tested polylactic acid filaments and FFF printer may serve as alternatives to those fabricated with the tested resin and vat polymerization printer, given the small and potentially clinically irrelevant differences in surface deviations and clinically acceptable mean positional deviations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Dep…
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey. Electr…
- Department of Prosthodontics, Faculty of Dentistry, Lokman Hekim University, Ankara, Turkey.
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; Department of Advanced Digital Dental Technology, Biruni University Advanced Technology and Research Center (BAMER), Biruni Univer…
- Department of Prosthodontics, Faculty of Dentistry, İstanbul Kent University, Istanbul, Turkey.
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Zitieren
APA
Çakmak, G., Dönmez, M. B., Ersöz, E., Diken Türksayar, A. A., Arınç, H., Adali, U., Yilmaz, B., & Pieralli, S. (2026). Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication. Journal of Dentistry. https://doi.org/10.1016/j.jdent.2026.106571
Vancouver
Çakmak G, Dönmez MB, Ersöz E, Diken Türksayar AA, Arınç H, Adali U, et al. Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication. Journal of Dentistry. 2026. doi:10.1016/j.jdent.2026.106571
BibTeX
@article{akmak2026,
author = {Çakmak, Gülce and Dönmez, Mustafa Borga and Ersöz, Ece and Diken Türksayar, Almira Ada and Arınç, Hakan and Adali, Ufuk and Yilmaz, Burak and Pieralli, Stefano},
title = {Evaluation of surface and positional trueness of removable dies fabricated through fused filament fabrication},
journal = {Journal of Dentistry},
year = {2026},
doi = {10.1016/j.jdent.2026.106571}
}
EUVIMED