Accuracy and resolution of conventional and additively manufactured silicone elastomers as applied in maxillofacial therapies
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.04.003 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Jenna C Hubacz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Advanced Prosthodontics Program, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tenn. Hauptthemen laut MEDLINE: Silicone Elastomers, Maxillofacial Prosthesis, Computer-Aided Design, Printing, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Silicone elastomers are becoming more readily available for additive manufacturing, which may be advantageous for fabricating maxillofacial prostheses. However, the properties of three-dimensionally (3D) printed silicone as compared with conventionally processed silicone have not been well studied. PURPOSE: The purpose of this in vitro study was to compare the dimensional accuracy and surface resolution of additively manufactured with conventional room-temperature vulcanized (RTV) silicones. MATERIAL AND METHODS: A custom aluminum mold was used to generate hand-spatulated specimens (A103 and VerSilTal-50F, n=20). A computer-aided design and computer-aided manufacturing workflow was used to generate additively manufactured specimens (Sil30 and TrueSil, n=20). Digital surface scans of each specimen were recorded; a scan of the mold served as the control. Surface dimensions were measured with a digital metrology software program, while digital overlays were made using a 3D processing software program. The surface resolution of the specimens was assessed by analyzing 4 topographical landmarks (flat surfaces, raised lines, domes, and scribed lines) with a visual qualitative grading scale. The data were analyzed with 1-way analysis of variance, followed by a Student-Newman-Keuls post hoc test (α=.05). RESULTS: The specimens demonstrated statistical differences in trueness and precision (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Resident, Advanced Prosthodontics Program, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tenn.
- Assistant Professor and Implantology Director, Department of Prosthodontics, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tenn.
- Director, Peterson Area Dental Laboratory, United States Air Force, Peterson Space Force Base, Colorado Springs, Colo.; and Military Consultant to the Air Force Surgeon General for Dental Laboratories, Air Force Medical…
- Professor, Director of Biomaterials Research, Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, Tenn. Electronic address: antheun@uthsc.edu.
Zitieren
APA
Hubacz, J. C., Gullard, A., Sheridan, R. R., & Versluis, A. (2025). Accuracy and resolution of conventional and additively manufactured silicone elastomers as applied in maxillofacial therapies. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.04.003
Vancouver
Hubacz JC, Gullard A, Sheridan RR, Versluis A. Accuracy and resolution of conventional and additively manufactured silicone elastomers as applied in maxillofacial therapies. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.04.003
BibTeX
@article{Hubacz2025,
author = {Hubacz, Jenna C and Gullard, Angela and Sheridan, Ryan R and Versluis, Antheunis},
title = {Accuracy and resolution of conventional and additively manufactured silicone elastomers as applied in maxillofacial therapies},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.04.003}
}
EUVIMED