Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study
The Journal of Indian Prosthodontic Society · 2025
DOI: 10.4103/jips.jips_203_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Indian Prosthodontic Society, 2025. Verfasst von Ganesh Ramkumar Rajapandi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, SRM Dental College, Ramapuram, Bharathi Salai, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Ketones, Polyethylene Glycols, Shear Strength, Silicones. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Aim
To evaluate and compare the shear bond strength between polyether ether ketone (PEEK) and maxillofacial silicone after cathodic arc plasma spraying and accelerated aging. Settings and Design: An in vitro study. Materials and Methods: According to ISO 10477:2020, 72 PEEK specimens were fabricated using computer-aided design/computer-aided manufacturing with 10-mm diameter and 3-mm thickness, and the silicone specimens were made with 5-mm diameter with 2.5-mm height. The specimens were categorized into Group 1 - No surface treatment, Group 2 - Cathodic arc plasma spraying, and Group 3 - Primer application. The silicone specimens were bonded to PEEK and subjected to accelerated aging for 252 and 504 h. The shear bond strength was performed using a universal testing machine at 1 mm/min crosshead speed. Statistical Analysis Used: One-way ANOVA, Tukey HSD test, and Student’s t -test, where P < 0.5 was set as significant.
Results
PEEK specimens subjected to primer application exhibited highest shear bond strength of 19.22 ± 0.35 Mpa, 18.55 ± 0.60 Mpa, 18.14 ± 0.65 Mpa, followed by cathodic arc plasma spraying 14.71 ± 0.28 Mpa, 13.54 ± 0.42 Mpa, 12.46 ± 0.48 Mpa after 24 h of fabrication, 252 h, and 504 h of aging and the least shear bond strength exhibited by control 4.98 ± 0.32, Mpa, 4.52 ± 0.33 Mpa, 4.2 ± 0.39 Mpa, respectively. The significance value P = 0.0001, which was
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, SRM Dental College, Ramapuram, Bharathi Salai, Chennai, Tamil Nadu, India.
Zitieren
APA
Rajapandi, G. R., Chidambaranathan, A. S., & Balasubramanium, M. (2025). Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_203_25
Vancouver
Rajapandi GR, Chidambaranathan AS, Balasubramanium M. Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study. The Journal of Indian Prosthodontic Society. 2025. doi:10.4103/jips.jips_203_25
BibTeX
@article{Rajapandi2025,
author = {Rajapandi, Ganesh Ramkumar and Chidambaranathan, Ahila Singaravel and Balasubramanium, Muthukumar},
title = {Effect of cathodic arc plasma spraying on shear bond strength between polyether ether ketone and maxillofacial silicone after accelerated aging - An in vitro study},
journal = {The Journal of Indian Prosthodontic Society},
year = {2025},
doi = {10.4103/jips.jips_203_25}
}
EUVIMED