EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study

Shasha Jia, Guowei Wang, Yimin Zhao, Xiaojing Wang

The Journal of Prosthetic Dentistry · 2025-03 · 133 (3) · 771-779

DOI: 10.1016/j.prosdent.2023.04.027 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-03. Verfasst von Shasha Jia und 3 weiteren Autor:innen. Beteiligte Einrichtung: Post-Graduate, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; Post-Graduate, Oral and Maxillofaci…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Surgery, Computer-Assisted, Robotic Surgical Procedures, Dental Implants. Die Arbeit wurde bisher 71-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The accuracy of implant placement is a prerequisite for prosthetically driven implant surgery and is necessary to ensure the long-term stability of dental implants. Imprecise implant position may bring difficulties for restoration, damage anatomic structures, affect peri-implant tissues, and lead to ultimate implant failure. PURPOSE: The purpose of this retrospective clinical study was to compare the accuracy of implants placed with an autonomous dental implant robotic (ADIR) system with those placed with static computer assisted implant surgery (sCAIS). MATERIAL AND METHODS: Thirty-nine participants were enrolled in this retrospective study: 20 participants had received implant surgery with the ADIR system and 19 participants had implants placed with sCAIS. The preoperative plans and postoperative cone beam computed tomography (CBCT) scans after implant placement were matched during the study. The coronal, apical, and angular deviations were measured and analyzed. A linear regression model was established to analyze the source of deviation. MANOVA was used to compare differences in the major outcome variables (α=.05). RESULTS: A total of 60 implants were placed in 39 participants (30 in each of the 2 groups). The mean ±standard deviation coronal, apical, and angular deviation of the ADIR system group and sCAIS group were 0.43 ±0.18 mm versus 1.31 ±0.62 mm (P .05). No complications were observed. CONCLUSIONS: The accuracy of the implant position using the ADIR system was significantly higher than with sCAIS, suggesting that the ADIR system can achieve minimally invasive and excellent accuracy. In addition, implant regions had no significant influence on the accuracy of implant placement. (Keywords: Robotic system, Implant surgery, Static guide, Autonomous, Accuracy).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousSurgery, Computer-AssistedRobotic Surgical ProceduresDental ImplantsHumansRetrospective StudiesMaleFemaleMiddle AgedCone-Beam Computed TomographyAdultAged

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Post-Graduate, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; Post-Graduate, Oral and Maxillofacial Surgery Teaching and Research Section, School of Stomatology, Qingd…
  • Associate Professor, Department of Stomatology, No. 971 Hospital of the Chinese Navy, Qingdao, Shandong, PR China.
  • Professor, State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Digital Dentistry, Center, School of Stomatology, The Fourth Militar…
  • Associate Professor, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; Associate Professor, Oral and Maxillofacial Surgery Teaching and Research Section, School of Stomat…

Zitieren

APA

Jia, S., Wang, G., Zhao, Y., & Wang, X. (2025). Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study. The Journal of Prosthetic Dentistry, 133(3), 771-779. https://doi.org/10.1016/j.prosdent.2023.04.027

Vancouver

Jia S, Wang G, Zhao Y, Wang X. Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study. The Journal of Prosthetic Dentistry. 2025;133(3):771-779. doi:10.1016/j.prosdent.2023.04.027

BibTeX
@article{Jia2025,
  author = {Jia, Shasha and Wang, Guowei and Zhao, Yimin and Wang, Xiaojing},
  title = {Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  volume = {133},
  number = {3},
  pages = {771--779},
  doi = {10.1016/j.prosdent.2023.04.027}
}
Kostenlos starten →