EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study

Jianping Chen, Yude Ding, Ruijue Cao, Yuchen Zheng, Liheng Shen iD, Linhong Wang iD, Fan Yang iD

Clinical Oral Implants Research · 2025

DOI: 10.1111/clr.14420 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Jianping Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Robotic Surgical Procedures, Dental Implants, Single-Tooth, Surgical Navigation Systems. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Major Scientific and Technological Project of Zhejiang Province, Zhejiang Provincial Key R&D Program (Leading Goose Projects), Key Research and Development Program of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This clinical retrospective study aimed to compare the deviations in single‐tooth implant placement using novel semi‐autonomous robotic‐assisted surgery system (sa‐RASS) and dynamic navigation system (DNS) methods. Materials and Methods A retrospective analysis of medical records from January to December 2023 was conducted to compare the implantation accuracy of the sa‐RASS and DNS in partially edentulous patients using cone‐beam computed tomography. Platform, apex, and angular deviations were measured and analyzed. The Kolmogorov–Smirnov test was used to check the data distribution, along with t ‐tests or Mann–Whitney U‐tests, where appropriate.

Results

Fifty‐seven patients (57 implants) were analyzed: 29 (29 implants) in the sa‐RASS group and 28 (28 implants) in the DNS group. The comparison of platform, apex, and angular deviation between the sa‐RASS group and DNS group were 0.91 ± 0.46 mm vs. 1.26 ± 0.51 mm ( p < 0.001), 1.06 ± 0.60 mm vs. 1.51 ± 0.56 mm ( p < 0.001), and 3.07° ± 1.66° vs. 3.71° ± 1.64° ( p > 0.05), respectively. In addition, there was no significant difference in the accuracy of different implant regions (premolar, molar, maxilla, and mandible) or implant length ( p > 0.05).

Conclusions

In the present study, sa‐RASS implant placement showed better positional accuracy than DNS implant placement in platform and apex deviation, although these improvements in accuracy may have limited clinical relevance, suggesting that the sa‐RASS might be advantageous in dental implant surgery. Trial Registration: ClinicalTrials.gov identifier: ChiCTR2400085089

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousRobotic Surgical ProceduresDental Implants, Single-ToothSurgical Navigation SystemsSurgery, Computer-AssistedHumansRetrospective StudiesFemaleMaleCone-Beam Computed TomographyMiddle AgedAdultAged

Stichwörter der Autor:innen

accuracydynamic navigation systemimplant dentistrysemi‐autonomous robot

Autor:innen und Institutionen

  • Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.
  • Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China.

ORCID-Profile: Liheng Shen, Linhong Wang, Fan Yang

Förderung

  • Major Scientific and Technological Project of Zhejiang Province
  • Zhejiang Provincial Key R&D Program (Leading Goose Projects)
  • Key Research and Development Program of Zhejiang Province

Zitieren

APA

Chen, J., Ding, Y., Cao, R., Zheng, Y., Shen, L., Wang, L., & Yang, F. (2025). Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14420

Vancouver

Chen J, Ding Y, Cao R, Zheng Y, Shen L, Wang L, et al. Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14420

BibTeX
@article{Chen2025,
  author = {Chen, Jianping and Ding, Yude and Cao, Ruijue and Zheng, Yuchen and Shen, Liheng and Wang, Linhong and Yang, Fan},
  title = {Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  doi = {10.1111/clr.14420}
}
Kostenlos starten →