EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of Accuracy and Systematic Precision Between Autonomous Dental Robot and Static Guide: A Retrospective Study

Na Chen iD, Yuanyuan Wang, Huawei Zou, Yu Chen, Yuanding Huang iD

Clinical Implant Dentistry and Related Research · 2025

DOI: 10.1111/cid.70050 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, 2025. Verfasst von Na Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Stomatological Hospital of Chongqing Medical University, Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing Municipal Key L…. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Dental Implantation, Endosseous, Robotic Surgical Procedures. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to compare the implant placement accuracy and systematic precision between Robotic‐Assisted Implant Surgery (RAIS) and Fully Guided Static Computer‐Assisted Implant surgery (sCAIS), as well as to explore factors influencing implant placement accuracy. Materials and Methods Patients who underwent digital guided implant surgery between October 2022 and July 2024 were included in this study. The patients were divided into the RAIS and sCAIS groups. Post‐operative CBCT scans were performed to measure three‐dimensional (3D) deviations and overlap rate (OR) of each implant. The differences in 3D deviations and OR between the two CAIS methods were analyzed, along with factors that could impact implant accuracy, such as anterior versus posterior sites, maxilla versus mandible, bone defects, implant morphology, and free‐end sites.

Results

254 patients were enrolled, with 125 patients receiving 227 implants in the RAIS group and 129 patients receiving 227 implants in the sCAIS group. The RAIS group demonstrated significantly better performance than the sCAIS group in coronal global deviation (0.69 [0.52] mm vs. 0.97 [0.64] mm), apical global deviation (0.75 [0.57] mm vs. 1.40 [0.82] mm), angular deviation (1.51 [1.43]° vs. 3.44 [2.78]°), and OR (80 [17]% vs. 64 [20]%) ( p < 0.001). There were no significant differences between the two groups in coronal horizontal mesiodistal deviation at the anterior sites, nor in coronal horizontal mesiodistal and buccolingual deviations at the posterior sites.

Conclusion

In most edentulous cases, implant placement accuracy assisted by the RAIS system was significantly higher than that of the sCAIS system. The control of Coronal horizontal (mesiodistal) deviation by sCAIS is comparable to that of RAIS. Additionally, the RAIS system demonstrated better systematic precision.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedDental Implantation, EndosseousRobotic Surgical ProceduresHumansRetrospective StudiesFemaleMaleMiddle AgedAdultCone-Beam Computed TomographyAgedDental Implants

Stichwörter der Autor:innen

accuracyautonomous dental implant robotic surgerydigital guided surgeryfully guided static computer‐assisted implant surgerysystematic precision

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Stomatological Hospital of Chongqing Medical University, Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqin…

ORCID-Profile: Na Chen, Yuanding Huang

Zitieren

APA

Chen, N., Wang, Y., Zou, H., Chen, Y., & Huang, Y. (2025). Comparison of Accuracy and Systematic Precision Between Autonomous Dental Robot and Static Guide: A Retrospective Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.70050

Vancouver

Chen N, Wang Y, Zou H, Chen Y, Huang Y. Comparison of Accuracy and Systematic Precision Between Autonomous Dental Robot and Static Guide: A Retrospective Study. Clinical Implant Dentistry and Related Research. 2025. doi:10.1111/cid.70050

BibTeX
@article{Chen2025,
  author = {Chen, Na and Wang, Yuanyuan and Zou, Huawei and Chen, Yu and Huang, Yuanding},
  title = {Comparison of Accuracy and Systematic Precision Between Autonomous Dental Robot and Static Guide: A Retrospective Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  doi = {10.1111/cid.70050}
}
Kostenlos starten →