Influence of ambient temperature changes on intraoral scanning accuracy
The Journal of Prosthetic Dentistry · 2023-11 · 130 (5) · 755-760
DOI: 10.1016/j.prosdent.2022.01.012 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023-11. Verfasst von Marta Revilla-León und 6 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor Graduate Prosthodontics, Department of Restorative Dentistry, School of Density, University of Washington, Seattle, Was…. Hauptthemen laut MEDLINE: Computer-Aided Design, Imaging, Three-Dimensional. Die Arbeit wurde bisher 133-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Different variables that decrease the accuracy of intraoral scanners (IOSs) have been identified. Ambient temperature changes can occur in the dental environment, but the impact of ambient temperature changes on intraoral scanning accuracy is unknown. PURPOSE: The purpose of this in vitro study was to assess the impact of ambient temperature changes on the accuracy (trueness and precision) of an IOS. MATERIAL AND METHODS: A complete arch maxillary dentate Type IV stone cast was obtained. Four 6-mm-diameter gauge balls were added to the maxillary cast to aid future evaluation measurements. The maxillary cast was digitized by using an industrial scanner (GOM Atos Q 3D 12M). The manufacturer's recommendations were followed in obtaining a reference scan. Then, the maxillary cast was digitized by using an IOS (TRIOS 4) according to the scanning protocol recommended by the manufacturer. Four groups were created depending on the ambient temperature change assessed: 24 °C or room temperature (24-D or control group), 19 °C or a 5-degree temperature drop (19-D group), 15 °C or a 9-degree temperature drop (15-D group), and 29 °C or a 5-degree temperature rise (29-D group). The Shapiro-Wilk and Kolmogorov-Smirnov tests revealed that the data were not normally distributed (P .999), indicating that precision wise the 4 groups were not significantly different from each other. CONCLUSIONS: Ambient temperature changes had a detrimental effect on the accuracy (trueness and precision) of the IOS tested. Ambient temperature changes significantly decreased the scanning accuracy of the IOS system tested. Increasing the ambient temperature has a greater influence on the intraoral scanning accuracy of the IOS selected when compared with decreasing the ambient temperature.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Affiliate Assistant Professor Graduate Prosthodontics, Department of Restorative Dentistry, School of Density, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, W…
- Predoctoral student, College of Dentistry, Texas A&M University, Dallas, Texas.
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
- Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
- Professor and Chair Department of Prosthodontics, Tuff University School of Dental Medicine, Boston, Mass.
Zitieren
APA
Revilla-León, M., Gohil, A., Barmak, A. B., Gómez-Polo, M., Pérez-Barquero, J. A., Att, W., & Kois, J. C. (2023). Influence of ambient temperature changes on intraoral scanning accuracy. The Journal of Prosthetic Dentistry, 130(5), 755-760. https://doi.org/10.1016/j.prosdent.2022.01.012
Vancouver
Revilla-León M, Gohil A, Barmak AB, Gómez-Polo M, Pérez-Barquero JA, Att W, et al. Influence of ambient temperature changes on intraoral scanning accuracy. The Journal of Prosthetic Dentistry. 2023;130(5):755-760. doi:10.1016/j.prosdent.2022.01.012
BibTeX
@article{RevillaLen2023,
author = {Revilla-León, Marta and Gohil, Aishwa and Barmak, Abdul B and Gómez-Polo, Miguel and Pérez-Barquero, Jorge Alonso and Att, Wael and Kois, John C},
title = {Influence of ambient temperature changes on intraoral scanning accuracy},
journal = {The Journal of Prosthetic Dentistry},
year = {2023},
volume = {130},
number = {5},
pages = {755--760},
doi = {10.1016/j.prosdent.2022.01.012}
}
EUVIMED