Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?
The Journal of Prosthetic Dentistry · 2023-04 · 129 (4) · 637.e1-637.e9
DOI: 10.1016/j.prosdent.2023.01.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2023-04. Verfasst von Andrea Baldi und 6 weiteren Autor:innen. Beteiligte Einrichtung: PhD student, Department of Surgical Sciences, Dental School, Turin, Italy. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Computer-Aided Design. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Intraoral scanners (IOSs) are widely used for partial-coverage adhesive restorations, but data on their performance in such preparations with complex geometries are sparse. PURPOSE: The purpose of this in vitro study was to investigate whether the partial-coverage adhesive preparation design and finish line depth affect the trueness and precision of different IOSs. MATERIAL AND METHODS: Seven partial-coverage adhesive preparation designs (4 different onlays, 2 endocrowns, and 1 occlusal veneer) were tested on copies of the same tooth placed in a typodont mounted on a mannequin. Each preparation was scanned 10 times with 6 different IOSs (total 420 scans) under the same light conditions. Trueness and precision, defined according to the International Organization for Standardization (ISO) 5725-1 standard, were analyzed with a best-fit algorithm by superimposition. The obtained data were analyzed by a 2-way analysis of variance to examine the effects of partial-coverage adhesive preparation design, IOS, and their interactions (α=.05). RESULTS: Significant differences were found among different preparation designs and IOSs (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- PhD student, Department of Surgical Sciences, Dental School, Turin, Italy.
- Adjunct Professor, Department of Surgical Sciences, Dental School, Turin, Italy.
- Lecturer, Department of Surgical Sciences, Dental School, Turin, Italy.
- Adjunct Professor, Department of Restorative Dentistry, Division of Prosthodontics, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
- Associate Professor, Department of Restorative Dentistry, Division of Prosthodontics, Federal University of Santa Maria (UFSM), Santa Maria, Brazil.
- Associate Professor, Department of Surgical Sciences, Dental School, Turin, Italy. Electronic address: nicola.scotti@unito.it.
Zitieren
APA
Baldi, A., Comba, A., Rozzi, D., Rocha Pereira, G. K., Valandro, L. F., Michelotto Tempesta, R., & Scotti, N. (2023). Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?. The Journal of Prosthetic Dentistry, 129(4), 637.e1-637.e9. https://doi.org/10.1016/j.prosdent.2023.01.017
Vancouver
Baldi A, Comba A, Rozzi D, Rocha Pereira GK, Valandro LF, Michelotto Tempesta R, et al. Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?. The Journal of Prosthetic Dentistry. 2023;129(4):637.e1-637.e9. doi:10.1016/j.prosdent.2023.01.017
BibTeX
@article{Baldi2023,
author = {Baldi, Andrea and Comba, Allegra and Rozzi, Davide and Rocha Pereira, Gabriel Kalil and Valandro, Luiz Felipe and Michelotto Tempesta, Riccardo and Scotti, Nicola},
title = {Does partial adhesive preparation design and finish line depth influence trueness and precision of intraoral scanners?},
journal = {The Journal of Prosthetic Dentistry},
year = {2023},
volume = {129},
number = {4},
pages = {637.e1--637.e9},
doi = {10.1016/j.prosdent.2023.01.017}
}
EUVIMED