Prospective observational analysis of intraoperative radiation exposure with a mini C-arm intensifier in percutaneous forefoot surgery
Orthopaedics & Traumatology: Surgery & Research · 2023-12 · 109 (8) · 103705
DOI: 10.1016/j.otsr.2023.103705 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Orthopaedics & Traumatology: Surgery & Research, 2023-12. Verfasst von Tristan Duguay und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinique du Landy, 23, rue du Landy, 93400 Saint-Ouen-sur-Seine, France. Electronic address: tristanduguay@gmail.com. Hauptthemen laut MEDLINE: Radiation Exposure, Radiation Protection, Occupational Exposure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Percutaneous forefoot surgery has been associated with higher radiation exposure than the conventional approach. However, there is little data on forefoot surgery using a mini C-arm intensifier. We, therefore, conducted a prospective study to (1) evaluate the intraoperative radiation received by the surgeon during percutaneous forefoot surgery with a mini C-arm; (2) compare the radiation received by the surgeon with the guidelines for occupational exposure issued by the International Commission on Radiological Protection (ICRP) (20 millisieverts per year [mSv/year] for the whole body, 500mSv/year for the hands, and 20mSv/year for the lens of the eye); and (3) compare the radiation received during percutaneous forefoot surgery with that of the open approach, which has already been reported in the literature. HYPOTHESIS: The radiation received by the surgeon during percutaneous forefoot surgery with a mini C-arm is lower than the ICRP guidelines, and the findings reported in the literature. MATERIALS AND METHODS: This prospective single-center study was conducted from September 2020 to May 2021. A total of 639 feet (i.e., 435 patients) were included. Of these 639 feet, 336 (52%) were hallux valgus repairs, 49 (8%) were stand-alone procedures of the lateral rays, and 124 (19%) were a combination of both. The radiation dose data was retrieved from the mini C-arm daily: dose-area product (DAP) in centigray per square centimeter (cGy/cm2) and radiation exposure duration in seconds. The doses received by the surgeon were collected every month by 4 passive dosimeters (hand, eye lens, and chest [on and under the lead apron]) and 2 active dosimeters (on and under the lead apron). RESULTS: The DAP emitted by the mini C-arm during an operating day was 0.10±0.01cGy/cm2 (range, 0.0-3.9), and the mean daily radiation duration was 34.7±19.3seconds (range, 0.7-226.8). There was a mean of 8±8 (range, 1-18) elective procedures per operating day. The daily reading on the active dosimeter worn on the lead apron was 0.002±0 microSv (range, 0-0.04), while the one worn under the apron was 0.001±0 microSv (range, 0-0.03). The equivalent doses over the 7-month study period for the hand, eye lens, and chest (over and under the apron) were 0.14mSv, 0mSv, 0.22mSv, and 0mSv, respectively. DISCUSSION/CONCLUSION: The radiation exposure in percutaneous forefoot surgery with a mini C-arm intensifier observed in our study was lower than the ICRP recommendations and literature findings during open surgery. LEVEL OF EVIDENCE: IV; prospective study without a control group.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinique du Landy, 23, rue du Landy, 93400 Saint-Ouen-sur-Seine, France. Electronic address: tristanduguay@gmail.com.
- Orthopaedic and Traumatologic Department, Hôpital Ambroise Paré, 9, avenue Charles de Gaulle, 92100 Boulogne-Billancourt, France.
- Orthopaedic and Traumatologic Department, Hôpital Lariboisière, 2, rue Ambroise Paré, 75010 Paris, France.
- Clinique du Sport, 36, boulevard Saint Marcel, 75005 Paris, France.
Zitieren
APA
Duguay, T., Housset, V., Bouché, P. A., Hardy, A., & Bauer, T. (2023). Prospective observational analysis of intraoperative radiation exposure with a mini C-arm intensifier in percutaneous forefoot surgery. Orthopaedics & Traumatology: Surgery & Research, 109(8), 103705. https://doi.org/10.1016/j.otsr.2023.103705
Vancouver
Duguay T, Housset V, Bouché PA, Hardy A, Bauer T. Prospective observational analysis of intraoperative radiation exposure with a mini C-arm intensifier in percutaneous forefoot surgery. Orthopaedics & Traumatology: Surgery & Research. 2023;109(8):103705. doi:10.1016/j.otsr.2023.103705
BibTeX
@article{Duguay2023,
author = {Duguay, Tristan and Housset, Victor and Bouché, Pierre Alban and Hardy, Alexandre and Bauer, Thomas},
title = {Prospective observational analysis of intraoperative radiation exposure with a mini C-arm intensifier in percutaneous forefoot surgery},
journal = {Orthopaedics & Traumatology: Surgery & Research},
year = {2023},
volume = {109},
number = {8},
pages = {103705},
doi = {10.1016/j.otsr.2023.103705}
}
EUVIMED