Evaluation of a real-time dose display system as a behavioural intervention to improve radiation protection in fluoroscopy: a pilot study

Keisuke Nagamoto iD, Yoshiki Suetsugu, Aina Yamamoto, Masaoki Kohzaki iD, Ryuji Okazaki iD

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncag050 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Keisuke Nagamoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiobiology and Hygiene Management, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, …. Hauptthemen laut MEDLINE: Radiation Protection, Occupational Exposure, Radiologists, Radiation Exposure. Die Arbeit nennt 28 Literaturangaben. Gefördert von: JSPS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This pilot study evaluated the educational and behavioural effects of a real-time radiation dose visualization system during upper gastrointestinal fluoroscopy. Fifty-one procedures (pre-intervention, n = 26; post-intervention, n = 25) by seven radiologists were analysed. Occupational dose Hp(10) showed no detectable difference after implementation [median 27 vs 26 μSv; median difference −2.0 μSv, 95% confidence intervals (CI) −11.0 to +7.0; P = .637]. The normalized index Hp(10)/cumulative air kerma (C-AK) was similarly unchanged (median 446.5 vs 450.9 μSv/Gy; difference +22.9 μSv/Gy, 95% CI −108.8 to +147.9; P = .785). Procedural metrics showed no significant variation (C-AK: P = .385; fluoroscopy time: P = .487; images: P = .084). Post-intervention questionnaires indicated increased awareness of radiation exposure and reinforcement of protective behaviour. The large-screen interface provided immediate, intuitive feedback and functioned as a behavioural safety tool aligned with experiential learning principles. Real-time visual feedback may enhance radiation protection education by improving awareness and promoting reflective behavioural learning, even when immediate reductions in measured dose are not observed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionOccupational ExposureRadiologistsRadiation ExposureHumansPilot ProjectsFluoroscopyRadiation DosageSurveys and Questionnaires

Autor:innen und Institutionen

  • Department of Radiobiology and Hygiene Management, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, Fukuoka, 807-8555, J…
  • Department of Radiology, Hospital of the University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu, Fukuoka, 807-8555, Japan.

ORCID-Profile: Keisuke Nagamoto, Masaoki Kohzaki, Ryuji Okazaki

Förderung

  • JSPS

Zitieren

APA

Nagamoto, K., Suetsugu, Y., Yamamoto, A., Kohzaki, M., & Okazaki, R. (2026). Evaluation of a real-time dose display system as a behavioural intervention to improve radiation protection in fluoroscopy: a pilot study. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag050

Vancouver

Nagamoto K, Suetsugu Y, Yamamoto A, Kohzaki M, Okazaki R. Evaluation of a real-time dose display system as a behavioural intervention to improve radiation protection in fluoroscopy: a pilot study. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag050

BibTeX
@article{Nagamoto2026,
  author = {Nagamoto, Keisuke and Suetsugu, Yoshiki and Yamamoto, Aina and Kohzaki, Masaoki and Okazaki, Ryuji},
  title = {Evaluation of a real-time dose display system as a behavioural intervention to improve radiation protection in fluoroscopy: a pilot study},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag050}
}
Kostenlos starten →