Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography
Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology · 2023
DOI: 10.1016/j.oooo.2023.01.011 ↗Kurz gefasst
Fachartikel in der Zeitschrift Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2023. Verfasst von Gamze Şirin Sarıbal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Assistant, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Erciyes University, Kayseri, Turkey. Electronic address: G.…. Hauptthemen laut MEDLINE: Radiation Protection. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 57 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: The objective was to compare the radiation protection effectiveness of a lead-free thermoplastic homopolymer (Anti-RAD) to conventional lead shielding in cone beam computed tomography (CBCT) exposures. STUDY DESIGN: Thermoluminescent dosimeters were placed on a human bone- and soft tissue-equivalent phantom to record equivalent doses in the thyroid gland, thyroid skin, and breast areas. CBCT images were obtained with the following 3 protocols: (1) without radiation shielding; (2) with 0.5-mm lead equivalent lead-containing shielding; and (3) with 0.5-mm lead equivalent Anti-RAD shielding. Independent t tests were used to evaluate the results. RESULTS: Compared with exposures without shielding, both lead and Anti-RAD protective devices reduced thyroid gland equivalent doses by approximately 40%, thyroid skin doses by approximately 75%, right breast skin doses by approximately 80%, and left breast skin doses by 75%. The differences in equivalent dose for both types of shielding compared with exposure with no shielding were statistically significant (P ≤ .042). However, there were no significant differences in dose reduction at any site between lead and Anti-RAD shielding (P ≥ .135). CONCLUSIONS: Radiation protection equivalent to lead can be provided with the Anti-RAD shield. With the use of this material, disadvantages such as damage to the aprons, lead toxicity, weight of lead aprons, and microbial contamination can be reduced.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Research Assistant, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Erciyes University, Kayseri, Turkey. Electronic address: G.sirin20@gmail.com.
- Associate Professor, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Erciyes University-Kayseri, Turkey.
- Department of Radiation Oncology, University of Erciyes Faculty of Medicine, Kayseri, Turkey.
Zitieren
APA
Sarıbal, G. Ş., Canger, E. M., & Yaray, K. (2023). Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. https://doi.org/10.1016/j.oooo.2023.01.011
Vancouver
Sarıbal GŞ, Canger EM, Yaray K. Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography. Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. 2023. doi:10.1016/j.oooo.2023.01.011
BibTeX
@article{Sarbal2023,
author = {Sarıbal, Gamze Şirin and Canger, Emin Murat and Yaray, Kadir},
title = {Evaluation of the radiation protection effectiveness of a lead-free homopolymer in cone beam computed tomography},
journal = {Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology},
year = {2023},
doi = {10.1016/j.oooo.2023.01.011}
}
EUVIMED