EUVIMEDEUVIMED entdecken
Crossref

Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom

Guolin Chen, Yuchen Yin, Liang Sun, Zichun Tang, Jianguo Chen iD

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Guolin Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Suzhou Stomatological Hospital, Gusu District, Suzhou 215000, China. Hauptthemen laut MEDLINE: Monte Carlo Method, Cone-Beam Computed Tomography, Phantoms, Imaging, Thyroid Gland. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, the effect of thyroid collars on radiation dose during dental cone-beam computed tomography (CBCT) was evaluated using Monte Carlo simulations and to calculate the effective dose underestimated for the actual CBCT examination due to accounting only for the head and neck. Three thyroid collar models that covered the surface of the phantom were established according to the International Commission on Radiological Protection (ICRP) adult-male mesh-type reference computational phantoms, and a Particle and Heavy Ion Transport code System was used to calculate the equivalent and effective doses of ICRP phantom when different thyroid shielding protocols were used in NewTom VGi evo CBCT, considering one medium (12 × 8 cm) and one small (8 × 5 cm) fields of view (FOVs), and two centre positions were used for each FOV. In four CBCT scanning scenarios, thyroid shielding reduced the equivalent dose for many tissues. The results indicate that the portion of the thyroid collar that wraps around the neck has the main role in reducing the effective dose during dental CBCT examinations, and the higher the axial level of the top of the shielding, the better the effectiveness of the shielding. In this study, the underestimation of the effective dose due to considering only the head and neck was 3.1%–8.1%, and the underestimation was more pronounced in larger FOVs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodCone-Beam Computed TomographyPhantoms, ImagingThyroid GlandRadiation ProtectionRadiation DosageHumansMaleAdultComputer SimulationRadiography, Dental

Autor:innen und Institutionen

  • Suzhou Stomatological Hospital, Gusu District, Suzhou 215000, China.
  • State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou Industrial Park, Suzhou 215123, China.
  • Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou Industrial Park, Suzhou 215123, China.

ORCID-Profile: Jianguo Chen

Zitieren

APA

Chen, G., Yin, Y., Sun, L., Tang, Z., & Chen, J. (2024). Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae206

Vancouver

Chen G, Yin Y, Sun L, Tang Z, Chen J. Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae206

BibTeX
@article{Chen2024,
  author = {Chen, Guolin and Yin, Yuchen and Sun, Liang and Tang, Zichun and Chen, Jianguo},
  title = {Monte Carlo simulation study of the effect of thyroid shielding on radiation dose in dental cone beam CT in an adult male phantom},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae206}
}
Kostenlos starten →