EUVIMEDEUVIMED entdecken
Crossref

Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study

Hassan Vafapour, Soraya Panah, Payman Rafiepour, Seyedeh Roghayeh Panahi iD

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae221 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Hassan Vafapour und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Sciences, School of Paramedical Sciences, Yasuj University of Medical Sciences, Beach Park towards Imam Sajjad Hospital, Shah…. Hauptthemen laut MEDLINE: Monte Carlo Method, Thyroid Gland, Radiation Protection, Phantoms, Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts. In this study, several materials were introduced as alternatives to lead thyroid shields. The results showed that Pb, Bi, Bi2O3, stainless steel, polyurethane-Bi2O3 (50%–50% mixture), and polyurethane-W (50%–50% mixture) shields provide a thyroid dose reduction of up to 12.0%, 12.3%, 12.0%, 11.6%, 11.8%, and 12.0%, respectively. For the truncated thyroid shields, these values are up to 10.5%, 10.3%, 10.3%, 9.80%, 10.0%, and 10.1%, respectively. Therefore, Bi and Bi2O3 can be suitable alternatives to lead thyroid shields.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Monte Carlo MethodThyroid GlandRadiation ProtectionPhantoms, ImagingRadiation DosageLeadHumansRadiography, PanoramicComputer SimulationBismuthPolyurethanesStainless Steel

Substanzen

LeadBismuthPolyurethanesStainless Steel

Autor:innen und Institutionen

  • Department of Radiation Sciences, School of Paramedical Sciences, Yasuj University of Medical Sciences, Beach Park towards Imam Sajjad Hospital, Shahid Zarei Educational Campus, Yasuj, Iran.
  • Department of Oral and Maxillofacial Radiology, School of Dentistry, Yasuj University of Medical Sciences, Dr. Shahid Jalil St., Yasuj, Kohgiluyeh and Boyer-Ahmad Province, Iran.
  • Department of Nuclear Engineering, School of Mechanical Engineering, Shiraz University, Namazi square, Mollasadra's street, Faculty of Mechanical Engineering, 7193616548, Shiraz, Iran.

ORCID-Profile: Seyedeh Roghayeh Panahi

Zitieren

APA

Vafapour, H., Panah, S., Rafiepour, P., & Panahi, S. R. (2024). Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae221

Vancouver

Vafapour H, Panah S, Rafiepour P, Panahi SR. Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae221

BibTeX
@article{Vafapour2024,
  author = {Vafapour, Hassan and Panah, Soraya and Rafiepour, Payman and Panahi, Seyedeh Roghayeh},
  title = {Assessment of thyroid dose in orthopantomogram imaging with different thyroid shield materials: a Monte Carlo simulation study},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae221}
}
Kostenlos starten →