Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability
Nefrología (English Edition) · 2024
DOI: 10.1016/j.nefroe.2024.11.024 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Nefrología (English Edition), 2024. Verfasst von María Ángeles Fernández Rojo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: mdefr@sescam.jccm.es. Hauptthemen laut MEDLINE: Renal Dialysis, Hemodynamics, Hemodynamic Monitoring. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Adequate control of patient blood volume in hemodialysis (HD) is essential as a modifiable risk factor for morbidity and mortality. In this study, we propose continuous non-invasive hemodynamic monitoring using bioreactance (Starling SV.Baxter) and real-time characterization of cardiac preload data to aid in the accurate assessment of volume status and improvement of tolerance in HD. METHODOLOGY: Observational and prospective study on the relationship between cardiac preload data and intradialytic hemodynamic instability. Forty-six stable HD patients were recruited. Clinical, analytical, and dialysis data were collected from all participants. The protocol included bioimpedance (BIVA), pre- and post-dialysis echocardiography and tissue Doppler, and monitoring of hemodynamic parameters during the session. RESULTS: According to the Fall20 definition, 24 patients (51.19%) experienced intradialytic hypotension (IDH). We found no relationship between IDH and analytical, echocardiographic, BIVA parameters, or relative blood volume measurement (BVM) values. Regarding hemodynamic monitoring, indexed systolic volume (ISV) was lower in patients with IDH (38.2 ± 0.9 vs. 39.2 ± 1.9; p < 0.001). Indexed systolic volume variation (ISVV) and heart rate (HR) were higher in the IDH group (14.1 ± 0.7 vs. 13.5 ± 0.7; p < 0.0001), (70.01 ± 2.1 vs. 68.97 ± 1.1; p < 0.0001), respectively. Indexed cardiac output (ICO) and indexed peripheral resistances (IPR) were also lower in the IDH group (2.62 ± 0.09 vs. 2.65 ± 0.13; p < 0.05) and (3201 ± 325 vs. 3432 ± 231; p < 0.05), respectively. Patients who started the session with lower preload (ΔSV after infusion of 250 cc ≥ 10%) more frequently developed IDH (p < 0.001). CONCLUSIONS: Non-invasive hemodynamic monitoring and preload data may constitute a valid tool in managing the volume status of HD patients and preventing IDH.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: mdefr@sescam.jccm.es.
- Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: rdtejeiro@gmail.com.
- Servicio Cardiología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: mario.baquero@gmail.com.
- Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: dabaibar@sescam.jccm.es.
- Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: lcueto@sescam.jccm.es.
- Servicio de Nefrología, Hospital Universitario de Toledo, Toledo, Spain. Electronic address: icarmena@sescam.jccm.es.
Zitieren
APA
Rojo, M. Á. F., Izquierdo, R. D., Alonso, M. V., Rodríguez, D. R., Bravo, L. C., Rodríguez, I. C., Herrero, D. C., Reina, C. J. C., & Hormigos, F. J. A. (2024). Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability. Nefrología (English Edition). https://doi.org/10.1016/j.nefroe.2024.11.024
Vancouver
Rojo MÁF, Izquierdo RD, Alonso MV, Rodríguez DR, Bravo LC, Rodríguez IC, et al. Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability. Nefrología (English Edition). 2024. doi:10.1016/j.nefroe.2024.11.024
BibTeX
@article{Rojo2024,
author = {Rojo, María Ángeles Fernández and Izquierdo, Rafael Díaz-Tejeiro and Alonso, Mario Vaquero and Rodríguez, Dabaiba Regidor and Bravo, Laura Cueto and Rodríguez, Iván Carmena and Herrero, David Carro and Reina, Carlos Jesús Cabeza and Hormigos, Francisco Javier Ahijado},
title = {Intradialytic non-invasive hemodynamic monitoring: usefulness of cardiac preload values in predicting hemodynamic instability},
journal = {Nefrología (English Edition)},
year = {2024},
doi = {10.1016/j.nefroe.2024.11.024}
}