EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Predictive vs. Flow-Derived Haemodynamic Monitoring in Major Abdominal Surgery: Associations with Intraoperative Hypotension and Postoperative Outcomes

Alejandro Martín-Arrabal, Francisco M Peinado iD, Miguel A Arrabal-Polo, Antonio J Gálvez-Muñoz iD, Tomás Saz-Terrado, María M Olvera-García, María S Serrano-Atero, Simón López-Soto, Mariana F Fernández iD

Medical Sciences · 24.04.2026 · 14 (2) · 210

DOI: 10.3390/medsci14020210 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Medical Sciences, online erschienen am 24.04.2026. Verfasst von Alejandro Martín-Arrabal und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, San Cecilio Clinical University Hospital, 18007 Granada, Spain. Hauptthemen laut MEDLINE: Hypotension, Abdomen, Hemodynamics, Monitoring, Intraoperative. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union—European Social Fund Plus, Ministerio de Universidades.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intraoperative hypotension (IOH) is a frequent manifestation of haemodynamic instability during general anaesthesia. Advances in arterial waveform analysis have led to two distinct monitoring strategies: flow-derived platforms and predictive algorithms designed to anticipate hypotension. However, prospective comparisons and their associations with IOH and postoperative outcomes remain limited. The objective was to compare predictive haemodynamic monitoring using the Hypotension Prediction Index (HPI) with flow-derived monitoring using the Vigileo/FloTrac system and to evaluate their associations with IOH and postoperative outcomes.

Methods

In this single-center prospective observational study, 101 adults undergoing elective major abdominal surgery under general anaesthesia were monitored using either the HPI system (n = 49) or the Vigileo/FloTrac system (n = 52). Primary outcomes were cumulative duration and frequency of IOH (mean arterial pressure < 65 mmHg). Secondary outcomes included postoperative complications, organ injury biomarkers (troponin, creatinine, eGFR), and hospital length of stay. Multivariable regression models adjusted for predefined confounders were used to estimate associations.

Results

Vigileo/FloTrac monitoring, compared with HPI, was independently associated with a greater cumulative duration of IOH (adjusted β = 1.66; 95% CI, 0.63–2.72) and a higher number of hypotensive episodes (adjusted β = 0.53; 95% CI, 0.10–0.95). Monitoring strategy was not associated with surgical site, respiratory, or neurological complications. However, Vigileo/FloTrac monitoring was associated with higher odds of vascular complications (adjusted OR = 4.36; 95% CI, 1.13–20.41). No significant associations were observed between monitoring strategy and postoperative organ injury biomarkers or length of hospital stay.

Conclusions

Predictive haemodynamic monitoring using the HPI system was associated with lower IOH burden compared with the Vigileo/FloTrac system. However, these differences were not consistently accompanied by improvements in postoperative outcomes. Haemodynamic optimisation should be considered as one component within a broader, integrated perioperative management strategy. Further large-scale, multicenter prospective studies are warranted to clarify its impact on patient-centered outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypotensionAbdomenHemodynamicsMonitoring, IntraoperativeHemodynamic MonitoringIntraoperative ComplicationsHumansFemaleMaleMiddle AgedProspective StudiesAgedPostoperative Complications

Stichwörter der Autor:innen

Vigileo/FloTrac systemhaemodynamic monitoringhypotension prediction indexintraoperative hypotensionpostoperative outcomes

Autor:innen und Institutionen

  • Department of Anesthesiology, San Cecilio Clinical University Hospital, 18007 Granada, Spain.
  • Department of Surgical Specialties, Biochemical and Immunology, Faculty of Medicine, University of Málaga, 29071 Málaga, Spain.
  • Medical Oncology Clinical Management Unit, Málaga Biomedical Research Institute (IBIMA)-CIMES-UMA, Virgen de la Victoria University Hospital, 29010 Málaga, Spain.
  • Biosanitary Research Institute (ibs.GRANADA), 18016 Granada, Spain.
  • Centre for Biomedical Research (CIBM), University of Granada, 18016 Granada, Spain.
  • Consortium for Biomedical Research in Epidemiology and Public Health (CIBERESP), 28029 Madrid, Spain.

ORCID-Profile: Francisco M Peinado, Antonio J Gálvez-Muñoz, Mariana F Fernández

Förderung

  • European Union—European Social Fund Plus
  • Ministerio de Universidades

Zitieren

APA

Martín-Arrabal, A., Peinado, F. M., Arrabal-Polo, M. A., Gálvez-Muñoz, A. J., Saz-Terrado, T., Olvera-García, M. M., Serrano-Atero, M. S., López-Soto, S., & Fernández, M. F. (2026). Predictive vs. Flow-Derived Haemodynamic Monitoring in Major Abdominal Surgery: Associations with Intraoperative Hypotension and Postoperative Outcomes. Medical Sciences, 14(2), 210. https://doi.org/10.3390/medsci14020210

Vancouver

Martín-Arrabal A, Peinado FM, Arrabal-Polo MA, Gálvez-Muñoz AJ, Saz-Terrado T, Olvera-García MM, et al. Predictive vs. Flow-Derived Haemodynamic Monitoring in Major Abdominal Surgery: Associations with Intraoperative Hypotension and Postoperative Outcomes. Medical Sciences. 2026;14(2):210. doi:10.3390/medsci14020210

BibTeX
@article{MartnArrabal2026,
  author = {Martín-Arrabal, Alejandro and Peinado, Francisco M and Arrabal-Polo, Miguel A and Gálvez-Muñoz, Antonio J and Saz-Terrado, Tomás and Olvera-García, María M and Serrano-Atero, María S and López-Soto, Simón and Fernández, Mariana F},
  title = {Predictive vs. Flow-Derived Haemodynamic Monitoring in Major Abdominal Surgery: Associations with Intraoperative Hypotension and Postoperative Outcomes},
  journal = {Medical Sciences},
  year = {2026},
  volume = {14},
  number = {2},
  pages = {210},
  doi = {10.3390/medsci14020210}
}
Kostenlos starten →