Beobachtungsstudie in der Zeitschrift Hemodialysis International, 2025. Verfasst von Melanie K Schoutteten und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hasselt University, Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Diepenbeek, Belgium. Hauptthemen laut MEDLINE: Renal Dialysis, Electric Impedance, Hemodynamics, Hemodynamic Monitoring. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Prevention of hemodynamic complications during hemodialysis remains challenging. Although whole body bioimpedance is well established in fluid status assessment, its use for dynamic or continuous recordings is limited. A segmental approach may serve this purpose better. This study investigates which body segment is best targeted to measure bioimpedance for hemodynamic monitoring.
Methods
In this observational study, serial bioimpedance measurements were conducted on the whole body, lower leg, upper arm, and thorax of 15 patients during two hemodialysis sessions. The resistance component of bioimpedance was used to investigate the relationship with changes in volume and systolic blood pressure (SBP).
Findings
Predialysis to postdialysis changes in relative resistance between the two sessions revealed the lowest intraclass correlation coefficient for upper arm (0.023) and the highest for thoracic resistance (0.728). Correlation between ultrafiltration volume and relative resistance was comparable between upper arm and thoracic segment (0.538 [0.447–0.618] and 0.537 [0.446–0.617], both p < 0.001, respectively) and the highest for whole‐body and lower leg (0.697 [0.63–0.754] and 0.670 [0.598–0.731], both p < 0.001, respectively). In contrast, the correlation between changes in SBP and relative resistance was the highest in the thoracic segment (−0.33 [−0.432 to −0.219], p < 0.001) and the lowest for whole body measurements (−0.154 [−0.269 to −0.036], p = 0.01). In addition, multiple regression analysis indicated thoracic resistance as the best predictor for changes in SBP ( β = −0.261 [−0.353 to −0.126], p < 0.001).
Discussion
These findings suggest that the thorax is the most suitable region for segmental bioimpedance measurements to assess hemodynamic parameters. Thoracic bioimpedance may innovate the hemodynamic monitoring of hemodialysis patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hasselt University, Faculty of Biomedical and Life Sciences, Limburg Clinical Research Center/Mobile Health Unit, Diepenbeek, Belgium.
- Department of Future Health, Ziekenhuis Oost-Limburg, Genk, Belgium.
- Department of Health Research, Imec the Netherlands/Holst Center, Eindhoven, the Netherlands.
- Department of Geriatrics, Ghent University Hospital, Ghent, Belgium.
- Department of Nephrology, Jessa Ziekenhuis, Hasselt, Belgium.
- Imec Belgium, Leuven, Belgium.
ORCID-Profile: Melanie K Schoutteten
Zitieren
APA
Schoutteten, M. K., van der Heijden, P., Brys, A. D. H., De Moor, B., van Hoof, C., Langereis, G., Kooman, J. P., & Vandervoort, P. M. (2025). Hemodynamic Monitoring During Hemodialysis Using Bioimpedance: A Comparison of Changes in Resistance Between Different Body Segments. Hemodialysis International. https://doi.org/10.1111/hdi.13245
Vancouver
Schoutteten MK, van der Heijden P, Brys ADH, De Moor B, van Hoof C, Langereis G, et al. Hemodynamic Monitoring During Hemodialysis Using Bioimpedance: A Comparison of Changes in Resistance Between Different Body Segments. Hemodialysis International. 2025. doi:10.1111/hdi.13245
BibTeX
@article{Schoutteten2025,
author = {Schoutteten, Melanie K and van der Heijden, Patrick and Brys, Astrid D H and De Moor, Bart and van Hoof, Chris and Langereis, Geert and Kooman, Jeroen P and Vandervoort, Pieter M},
title = {Hemodynamic Monitoring During Hemodialysis Using Bioimpedance: A Comparison of Changes in Resistance Between Different Body Segments},
journal = {Hemodialysis International},
year = {2025},
doi = {10.1111/hdi.13245}
}
EUVIMED