EUVIMEDEUVIMED entdecken
LeitlinieOpen Access · CC BY 4.0

Aligning cardiac monitoring with American Heart Association Guidelines: Impact on utilization, hemodynamic monitoring, and outcomes

Brian Hilliard, Tanvi Mehta, James Grace, Deborah L Pestka iD, Nicholas E Ingraham iD, Timothy Beebe, Christopher Tignanelli, Genevieve B Melton, Nathan Shippee, Joseph S Koopmeiners, Michael Usher

PLOS One · 2026

DOI: 10.1371/journal.pone.0338943 ↗

Kurz gefasst

Leitlinie in der Zeitschrift PLOS One, 2026. Verfasst von Brian Hilliard und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, University of Minnesota Medical School, Minneapolis, Minnesota, United States of America. Hauptthemen laut MEDLINE: Hemodynamic Monitoring. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Overuse of continuous cardiac monitoring can lead to poor patient experience, increased costs, and decreased efficiency. Because significant variation in continuous cardiac monitoring ordering exists, implementation strategies that promote care in alignment with practice standards and an examination of use cases that fall outside of standards are needed. The purpose of this study, therefore, was to evaluate if implementation of American Heart Association (AHA) practice standards on continuous cardiac monitoring could reduce utilization without jeopardizing patient safety.

Methods

We conducted a prospective pre-post study including a 2 year prospectively collected baseline against a 10-month post intervention period within a 10-hospital health system. An electronic health record (EHR) order set was implemented to align care with AHA continuous cardiac monitoring practice standards. We compared continuous cardiac monitoring utilization, adherence to standards, as well as clinical outcomes including mortality and length of stay. Finally, we investigated the rate and impact of hemodynamically significant events (hypotension, bradycardia, and tachycardia) before and after the intervention.

Results

We compared 117,814 hospitalizations pre-implementation against 49,006 post implementation finding significant reductions in total telemetry use, and no significant change in outcomes. Overall, patients with telemetry use outside of standards had higher mortality, longer length of stay, and higher readmission rates. The intervention was associated with a higher rate of hypotensive events which occurred off cardiac monitoring. This was not associated with worse outcomes.

Conclusions

An EHR tool to align care with continuous cardiac monitoring practice standards safely reduced overall continuous cardiac monitoring utilization. Use outside of practice standards persisted and was primarily focused on monitoring for potential hemodynamic instability. We found no evidence that continuous cardiac monitoring was associated with improved outcomes in unstable patients. Continuous cardiac monitoring for potentially unstable patients can likely be replaced for non-cardiac indications with continuous heart rate monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hemodynamic MonitoringHumansAmerican Heart AssociationUnited StatesFemaleMaleProspective StudiesMiddle AgedTelemetryAgedLength of StayPractice Guidelines as TopicHemodynamicsElectronic Health Records

Autor:innen und Institutionen

  • Department of Medicine, University of Minnesota Medical School, Minneapolis, Minnesota, United States of America.
  • Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, Minnesota, United States of America.
  • Department of Surgery, University of Minnesota Medical School, Minneapolis, Minnesota, United States of America.
  • Center for Learning Health System Sciences, University of Minnesota Medical School, Minneapolis, Minnesota, United States of America.
  • Division of Health Policy Management, School of Public Health, University of Minnesota, Minneapolis, Minnesota, United States of America.
  • Institute for Health Informatics, University of Minnesota, Minneapolis, Minnesota, United States of America.

ORCID-Profile: Deborah L Pestka, Nicholas E Ingraham

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Hilliard, B., Mehta, T., Grace, J., Pestka, D. L., Ingraham, N. E., Beebe, T., Tignanelli, C., Melton, G. B., Shippee, N., Koopmeiners, J. S., & Usher, M. (2026). Aligning cardiac monitoring with American Heart Association Guidelines: Impact on utilization, hemodynamic monitoring, and outcomes. PLOS One. https://doi.org/10.1371/journal.pone.0338943

Vancouver

Hilliard B, Mehta T, Grace J, Pestka DL, Ingraham NE, Beebe T, et al. Aligning cardiac monitoring with American Heart Association Guidelines: Impact on utilization, hemodynamic monitoring, and outcomes. PLOS One. 2026. doi:10.1371/journal.pone.0338943

BibTeX
@article{Hilliard2026,
  author = {Hilliard, Brian and Mehta, Tanvi and Grace, James and Pestka, Deborah L and Ingraham, Nicholas E and Beebe, Timothy and Tignanelli, Christopher and Melton, Genevieve B and Shippee, Nathan and Koopmeiners, Joseph S and Usher, Michael},
  title = {Aligning cardiac monitoring with American Heart Association Guidelines: Impact on utilization, hemodynamic monitoring, and outcomes},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0338943}
}
Kostenlos starten →