EUVIMEDEUVIMED entdecken
Crossref

Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints

Yiqing Yin, Wenchen Wang, Guyue Zhou, Haotian Miao, Weimin Wang, Zheng Wang, Wenhui Yang, Feng Liu, Yaohui Wang

Magnetic Resonance Imaging · 2026-06 · 129 · 110654

DOI: 10.1016/j.mri.2026.110654 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-06. Verfasst von Yiqing Yin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China; School of Electronic, Electrical and Communication Engineeri…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Key Technologies Research and Development Program, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Strong shielding of gradient coils is required to maintain the cryogenic stability of superconducting magnetic resonance imaging (MRI) systems. In planar-type superconducting MRI systems, which extensive use high-conductivity materials, gradient coil sets are embedded within the open slots of the main magnet. In this study, we propose a shielding constraint based on a progressively enhanced shielding coil design method. This approach reduces complexity in coil structure while optimizing gradient coil performance and meeting imaging requirements within the specified diameter of the spherical volume (DSV). We measure the magnetic field distribution at the axial directions and magnetic field distributions produced by the designed gradient coils. Experimental results confirm that the proposed design suppresses stray magnetic fields without excessive coil complexity, while producing highly linear gradient fields in the imaging region.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingEquipment DesignSuperconductivityMagnetic FieldsPhantoms, ImagingEquipment Failure Analysis

Stichwörter der Autor:innen

Gradient coilMRIMagnetic shieldingSuperconducting magnet

Autor:innen und Institutionen

  • Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China.
  • School of Electrical Engineering and Computer Science, The University of Queensland, St Lucia, Brisbane, QLD 4072, Australia.
  • School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074…
  • School of Electronics & Institute of Biomedical Engineering, Peking University & Shenzhen Graduate School, Beijing 10049, China.
  • Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China.…

Förderung

  • Key Technologies Research and Development Program
  • National Natural Science Foundation of China

Zitieren

APA

Yin, Y., Wang, W., Zhou, G., Miao, H., Wang, W., Wang, Z., Yang, W., Liu, F., & Wang, Y. (2026). Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints. Magnetic Resonance Imaging, 129, 110654. https://doi.org/10.1016/j.mri.2026.110654

Vancouver

Yin Y, Wang W, Zhou G, Miao H, Wang W, Wang Z, et al. Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints. Magnetic Resonance Imaging. 2026;129:110654. doi:10.1016/j.mri.2026.110654

BibTeX
@article{Yin2026,
  author = {Yin, Yiqing and Wang, Wenchen and Zhou, Guyue and Miao, Haotian and Wang, Weimin and Wang, Zheng and Yang, Wenhui and Liu, Feng and Wang, Yaohui},
  title = {Actively shielded gradient coil design for an all-superconducting planar MRI system using progressively-enhanced shielding constraints},
  journal = {Magnetic Resonance Imaging},
  year = {2026},
  volume = {129},
  pages = {110654},
  doi = {10.1016/j.mri.2026.110654}
}
Kostenlos starten →