Parallel Cable‐Driven Prostate Puncture Robot: Design and Performance Evaluation

Yupeng Zou iD, Tianyu Lan, Yanxing Zhang, Xiaojing Lai, Zhishen Zhou, Changsheng Li iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Yupeng Zou und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Prostate, Punctures, Robotics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Research on key technologies of magnetic environment compatible parallel cable-driven puncture surgical robot.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The limited workspace and strong magnetic field inside MRI challenge the design of the prostate puncture robot. Simplifying the robot's structure is crucial.

Methods

This paper proposes a parallel cable‐driven (PCD) prostate puncture robot, and conducts a preliminary material design. The kinematics, statics and stiffness models of the robot are established. The wrench‐feasible workspace is also verified. Multibody simulation is used to analyse the robot's performance.

Results

Motion accuracy experiments were conducted in both planar and spatial configurations, followed by stiffness performance evaluation. During the phantom puncture experiment, the insertion point exhibited horizontal position errors of 0.35 mm and 0.4 mm.

Conclusion

The non‐parallel cable‐driven design not only simplifies the robotic structure for prostate puncture surgery but also ensures compatibility with strong magnetic fields. Furthermore, the robot exhibits high motion accuracy and superior stiffness performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresProstatePuncturesRoboticsMaleHumansEquipment DesignPhantoms, ImagingMagnetic Resonance ImagingBiomechanical PhenomenaMotionComputer SimulationMagnetic Fields

Stichwörter der Autor:innen

parallel cable‐drivenpuncture surgical robotsimulation and experiment validationwrench‐feasible workspace analysis

Autor:innen und Institutionen

  • College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao, China.
  • School of Mechatronical Engineering, Beijing Institute of Technology, Beijing, China.

ORCID-Profile: Yupeng Zou, Changsheng Li

Förderung

  • Research on key technologies of magnetic environment compatible parallel cable-driven puncture surgical robot

Zitieren

APA

Zou, Y., Lan, T., Zhang, Y., Lai, X., Zhou, Z., & Li, C. (2025). Parallel Cable‐Driven Prostate Puncture Robot: Design and Performance Evaluation. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70102

Vancouver

Zou Y, Lan T, Zhang Y, Lai X, Zhou Z, Li C. Parallel Cable‐Driven Prostate Puncture Robot: Design and Performance Evaluation. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70102

BibTeX
@article{Zou2025,
  author = {Zou, Yupeng and Lan, Tianyu and Zhang, Yanxing and Lai, Xiaojing and Zhou, Zhishen and Li, Changsheng},
  title = {Parallel Cable‐Driven Prostate Puncture Robot: Design and Performance Evaluation},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70102}
}