Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI
Magnetic Resonance Imaging · 2026-10 · 132 · 110701
DOI: 10.1016/j.mri.2026.110701 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026-10. Verfasst von Guyue Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, PR China; School of Electrical and Electronic…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
For high-field MRI, ensuring high fidelity between the as-built gradient field and the optimized design is critical for accurate gradient-field generation and spatial encoding. Conventional manufacturing approaches for gradient coils typically employ a copper-plate cutting and bending method, where a 2D unwrapped conductor pattern is reshaped into a cylindrical geometry. However, the bending process inevitably introduces geometric distortions, resulting in additional magnetic-field deviations. This study aims to develop a high-precision engineering approach that minimizes discrepancies between the magnetic fields produced by the designed patterns and the as-built coils. To this end, a mid-surface-based approach is proposed (i.e., the geometric mid-surface of the conductor thickness), in which the three-dimensional current paths are defined directly on the cylindrical mid-surface, thereby eliminating planar unfolding and subsequent bending assumptions. The methodology is demonstrated on an X-gradient coil designed for a 7 T superconducting MRI magnet with a 54 mm bore and a 25 mm DSV. Finite-element simulations show that the proposed approach substantially improves magnetic-field fidelity, reducing the maximum field deviation from 10.92% with the conventional copper-plate cutting and bending method to 3.71% with the mid-surface extrusion approach. Prototype gradient coils for the X, Y, and Z axes were fabricated and tested independently, yielding coefficients of determination of R2 > 0.997 for all three axes. These results confirm that the mid-surface-based approach provides a higher-fidelity conversion from stream-function contour patterns to manufacturable gradient coils, yielding improved as-built field accuracy and enhanced design-to-fabrication consistency in compact high-field MRI gradient systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, PR China; School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430…
- Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100190, PR China; School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, PR C…
- School of Information Technology and Electrical Engineering, The University of Queensland, St Lucia, Brisbane, QLD 4072, Australia.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zhou, G., Wang, Y., Wang, W., Yang, W., Miao, H., Song, X., Chen, S., Wang, H., Song, Y., & Liu, F. (2026). Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI. Magnetic Resonance Imaging, 132, 110701. https://doi.org/10.1016/j.mri.2026.110701
Vancouver
Zhou G, Wang Y, Wang W, Yang W, Miao H, Song X, et al. Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI. Magnetic Resonance Imaging. 2026;132:110701. doi:10.1016/j.mri.2026.110701
BibTeX
@article{Zhou2026,
author = {Zhou, Guyue and Wang, Yaohui and Wang, Wenchen and Yang, Wenhui and Miao, Haotian and Song, Xiaowei and Chen, Shunzhong and Wang, Hui and Song, Yunxing and Liu, Feng},
title = {Small-bore gradient coil design with plate-rolling error correction for use in micro-MRI},
journal = {Magnetic Resonance Imaging},
year = {2026},
volume = {132},
pages = {110701},
doi = {10.1016/j.mri.2026.110701}
}
EUVIMED