Susceptibility-matched padding improves the quality of cervical and lumbar spinal fMRI
Magnetic Resonance Imaging · 2026
DOI: 10.1016/j.mri.2026.110640 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2026. Verfasst von Olivia S Kowalczyk und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, De Crespigny Park, London SE5 8AF, UK; Functio…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Spinal Cord, Image Enhancement, Cervical Cord. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Medical Research Council (MRC), UK Research and Innovation Medical Research Council, King's College London.
Abstract (Originalsprache)
Spinal cord functional magnetic resonance imaging (fMRI) has advanced significantly in recent years, revealing insights into the function of somatosensory and motor systems. However, the complex environment of the spinal cord induces unique sources of noise, limiting the quality of spinal fMRI recordings. Various hardware and software solutions have been proposed to address these challenges. Among them, susceptibility-matched padding has gained popularity due its low cost, ease of use, and effectiveness in reducing static B 0 field inhomogeneities, which are a major source of artefacts in spinal fMRI. Despite anecdotal evidence, the impact of susceptibility-matched padding on the quality of spinal cord fMRI has not been assessed systematically. We investigated the effects of non-protonated perfluorocarbon liquid-filled padding (SatPad) on B 0 field homogeneity and functional echo-planar imaging (EPI) in cervical and lumbar spinal cord in 10 healthy volunteers. Participants underwent two resting-state fMRI scanning sessions, one per cord section. Within each session they were scanned with and without SatPad in a pseudo-randomised order. The use of SatPad increased B 0 field homogeneity and improved functional image quality metrics, including temporal signal-to-noise ratio, timeseries coefficient of variation, DVARS, and ghosting artefacts. While both cervical and lumbar cord data benefited from the use of SatPad, greater effects were observed in the cervical cord. These findings provide a compelling basis for integrating susceptibility-matched padding into routine spinal fMRI protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, De Crespigny Park, London SE5 8AF, UK; Functional Imaging Laboratory, Department of Imaging Neuroscience, UCL Queen…
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, De Crespigny Park, London SE5 8AF, UK.
Förderung
- Medical Research Council (MRC)
- UK Research and Innovation Medical Research Council
- King's College London
- National Institute for Health and Care Research
- South London and Maudsley NHS Foundation Trust
- NIHR Maudsley Biomedical Research Centre
Zitieren
APA
Kowalczyk, O. S., Howard, M. A., & Lythgoe, D. J. (2026). Susceptibility-matched padding improves the quality of cervical and lumbar spinal fMRI. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2026.110640
Vancouver
Kowalczyk OS, Howard MA, Lythgoe DJ. Susceptibility-matched padding improves the quality of cervical and lumbar spinal fMRI. Magnetic Resonance Imaging. 2026. doi:10.1016/j.mri.2026.110640
BibTeX
@article{Kowalczyk2026,
author = {Kowalczyk, Olivia S and Howard, Matthew A and Lythgoe, David J},
title = {Susceptibility-matched padding improves the quality of cervical and lumbar spinal fMRI},
journal = {Magnetic Resonance Imaging},
year = {2026},
doi = {10.1016/j.mri.2026.110640}
}
EUVIMED