Reducing Noise Induced by Cardiac Pulsatility in Brain Maps of R 2 * and Magnetic Susceptibility Using Tailored k‐space Sampling
NMR in Biomedicine · 2026-06 · 39 (6)
DOI: 10.1002/nbm.70305 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 10.05.2026. Verfasst von Quentin Raynaud und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Swi…. Hauptthemen laut MEDLINE: Brain, Heart, Magnetic Resonance Imaging, Signal-To-Noise Ratio. Die Arbeit nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Fondation Roger de Spoelberch.
Abstract (Originalsprache)
Maps of the transverse relaxation rate R 2 * and magnetic susceptibility ( χ ) are computed from gradient‐echo data and are sensitive to signal instabilities induced by cardiac pulsation. Here, we introduce two k‐space sampling strategies that aim to mitigate the impact of cardiac‐induced noise in brain maps of R 2 * and χ . The proposed strategies are based on the higher level of cardiac‐induced noise near the k‐space centre compared to the periphery. Using CArtesian trajectory with Spiral PRofile (CASPR), the first strategy allows for the acquisition of a specific number of averages at each k‐space location, derived from the local level of cardiac‐induced noise. The second strategy uses cardiac triggering to synchronize the acquisition near the k‐space centre with the cardiac cycle in real time. We compared the variability across four repetitions of R 2 * and χ maps computed from data acquired using both strategies and with a standard linear trajectory. Data were acquired in 10 healthy volunteers. Compared to linear trajectory, CASPR reduced the variability of R 2 * and χ maps across repetitions by 22% and 16% across the whole brain, reaching over 30% in inferior brain regions, for a 14% increase in scan time. CASPR also reduced the level of aliasing artefacts from pulsating blood vessels. Cardiac triggering did not reduce the variability of R 2 * or χ maps. CASPR can be designed to mitigate cardiac‐induced noise in brain maps of the MRI parameters R 2 * and χ . Synchronization of data acquisition with the cardiac cycle did not reduce the level of cardiac‐induced noise.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory for Research in Neuroimaging, Department for Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland.
- LTS5, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
ORCID-Profile: Rita Oliveira, Tobias Kober, Antoine Lutti
Förderung
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Fondation Roger de Spoelberch
Zitieren
APA
Raynaud, Q., Dardano, T., Oliveira, R., Di Domenicantonio, G., Kober, T., Roy, C. W., van Heeswijk, R. B., & Lutti, A. (2026). Reducing Noise Induced by Cardiac Pulsatility in Brain Maps of R 2 * and Magnetic Susceptibility Using Tailored k‐space Sampling. NMR in Biomedicine, 39(6). https://doi.org/10.1002/nbm.70305
Vancouver
Raynaud Q, Dardano T, Oliveira R, Di Domenicantonio G, Kober T, Roy CW, et al. Reducing Noise Induced by Cardiac Pulsatility in Brain Maps of R 2 * and Magnetic Susceptibility Using Tailored k‐space Sampling. NMR in Biomedicine. 2026;39(6). doi:10.1002/nbm.70305
BibTeX
@article{Raynaud2026,
author = {Raynaud, Quentin and Dardano, Thomas and Oliveira, Rita and Di Domenicantonio, Giulia and Kober, Tobias and Roy, Christopher W and van Heeswijk, Ruud B and Lutti, Antoine},
title = {Reducing Noise Induced by Cardiac Pulsatility in Brain Maps of R 2 * and Magnetic Susceptibility Using Tailored k‐space Sampling},
journal = {NMR in Biomedicine},
year = {2026},
volume = {39},
number = {6},
doi = {10.1002/nbm.70305}
}
EUVIMED