EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Motion and temporal B 0 ‐shift corrections for QSM and R2* mapping using dual‐echo spiral navigators and conjugate‐phase reconstruction

Yuguang Meng iD, Jason W Allen, Vahid Khalilzad Sharghi, Deqiang Qiu

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30266 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Yuguang Meng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Brain, Algorithms, Imaging, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS, National Institute on Aging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop an efficient navigator‐based motion and temporal B 0 ‐shift correction technique for 3D multi‐echo gradient‐echo (ME‐GRE) MRI for quantitative susceptibility mapping (QSM) and mapping. Theory and Methods A dual‐echo 3D stack‐of‐spiral navigator was designed to interleave with the Cartesian multi‐echo gradient‐echo acquisitions, allowing the acquisition of both low‐echo and high‐echo time signals. We additionally designed a novel conjugate phase–based reconstruction method for the joint correction of motion and temporal B 0 shifts. We performed numerical simulation, phantom scans, and in vivo human scans to assess the performance of the methods.

Results

Numerical simulation and human brain scans demonstrated that the proposed technique successfully corrected artifacts induced by both head motions and temporal B 0 changes. Efficient B 0 ‐change correction with conjugate‐phase reconstruction can be performed on fewer than 10 clustered k‐space segments. In vivo scans showed that combining temporal B 0 correction with motion correction further reduced artifacts and improved image quality in both and QSM images.

Conclusion

Our proposed approach of using 3D spiral navigators and a novel conjugate‐phase reconstruction method can improve susceptibility‐related measurements using MR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingBrainAlgorithmsImaging, Three-DimensionalMagnetic Resonance ImagingArtifactsComputer SimulationMotionHumansImage Processing, Computer-AssistedReproducibility of ResultsBrain Mapping

Stichwörter der Autor:innen

B0‐shiftQSMconjugate‐phase reconstructionmotion correctionparallel imaging

Autor:innen und Institutionen

  • Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA.
  • Department of Radiology and Imaging Sciences, Indiana University, Indianapolis, Indiana, USA.
  • Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Siemens Heathineers, Atlanta, Georgia, USA.

ORCID-Profile: Yuguang Meng

Förderung

  • NIA NIH HHS
  • National Institute on Aging

Zitieren

APA

Meng, Y., Allen, J. W., Sharghi, V. K., & Qiu, D. (2025). Motion and temporal B 0 ‐shift corrections for QSM and R2* mapping using dual‐echo spiral navigators and conjugate‐phase reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30266

Vancouver

Meng Y, Allen JW, Sharghi VK, Qiu D. Motion and temporal B 0 ‐shift corrections for QSM and R2* mapping using dual‐echo spiral navigators and conjugate‐phase reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30266

BibTeX
@article{Meng2025,
  author = {Meng, Yuguang and Allen, Jason W and Sharghi, Vahid Khalilzad and Qiu, Deqiang},
  title = {Motion and temporal B 0 ‐shift corrections for QSM and R2* mapping using dual‐echo spiral navigators and conjugate‐phase reconstruction},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30266}
}
Kostenlos starten →