EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Realistic In Silico Brain Phantom for Quantifying Susceptibility Anisotropy‐Induced Error in Susceptibility Separation

Daniel Ridani iD, Benjamin De Leener, Eva Alonso-Ortiz iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Daniel Ridani und 2 weiteren Autor:innen. Beteiligte Einrichtung: NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Phantoms, Imaging, Brain, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada, Canada First Research Excellence Fund, Fonds de recherche du Québec.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To create a realistic in silico brain phantom for positive and negative magnetic susceptibility that incorporates susceptibility anisotropy, enabling the evaluation of how susceptibility anisotropy influences susceptibility separation algorithm performance.

Methods

We expanded an existing QSM validation phantom by creating separate maps for positive and negative susceptibility, with the option of modeling susceptibility anisotropy. Multi‐echo gradient echo data were simulated to evaluate four susceptibility separation techniques (‐separation, DECOMPOSE‐QSM, APART‐QSM, and ‐QSM). To assess the impact of noise, simulations were performed at different SNR levels (50, 100, 200, 300).

Results

Our findings showed that the error in negative susceptibility estimates increased by up to 53% when susceptibility anisotropy was present, compared to the case without susceptibility anisotropy, with ‐separation being the algorithm that was most sensitive to anisotropy. Robustness to noise varied across the assessed algorithms, with APART‐QSM and ‐separation having the highest and lowest sensitivity to noise, respectively.

Conclusion

The modified phantom is open‐source and can serve as a numerical ground truth for evaluating susceptibility separation methods. Our findings emphasize the importance of incorporating susceptibility anisotropy into susceptibility separation models to improve their accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingBrainMagnetic Resonance ImagingImage Processing, Computer-AssistedAnisotropyAlgorithmsComputer SimulationHumansSignal-To-Noise RatioReproducibility of Results

Stichwörter der Autor:innen

MRI simulationsbrain phantomsusceptibility anisotropysusceptibility separation

Autor:innen und Institutionen

  • NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada.
  • CHU Sainte-Justine Research Center, Montreal, Quebec, Canada.
  • Department of Computer Engineering and Software Engineering, Polytechnique Montreal, Montreal, Quebec, Canada.
  • Department of Electrical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada.

ORCID-Profile: Daniel Ridani, Eva Alonso-Ortiz

Förderung

  • Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada
  • Canada First Research Excellence Fund
  • Fonds de recherche du Québec
  • Polytechnique Montreal
  • TransMedTech Institute
  • Polytechnique Montréal

Zitieren

APA

Ridani, D., De Leener, B., & Alonso-Ortiz, E. (2026). A Realistic In Silico Brain Phantom for Quantifying Susceptibility Anisotropy‐Induced Error in Susceptibility Separation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70468

Vancouver

Ridani D, De Leener B, Alonso-Ortiz E. A Realistic In Silico Brain Phantom for Quantifying Susceptibility Anisotropy‐Induced Error in Susceptibility Separation. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70468

BibTeX
@article{Ridani2026,
  author = {Ridani, Daniel and De Leener, Benjamin and Alonso-Ortiz, Eva},
  title = {A Realistic In Silico Brain Phantom for Quantifying Susceptibility Anisotropy‐Induced Error in Susceptibility Separation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70468}
}
Kostenlos starten →