EUVIMEDEUVIMED entdecken
Open Access

Noise decorrelation coil combination optimizes SNR of edited 1H MRS data

Amy E Bouchard, Mark Mikkelsen

Magnetic Resonance Imaging · 2025

DOI: 10.1016/j.mri.2025.110452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Amy E Bouchard und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Weill Cornell Medicine, New York, NY, United States. Hauptthemen laut MEDLINE: gamma-Aminobutyric Acid, Proton Magnetic Resonance Spectroscopy, Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Determining the optimal radiofrequency (RF) coil combination method for magnetic resonance spectroscopy (MRS) is crucial for maximizing the signal-to-noise ratio (SNR) and reliably detecting low-concentration metabolites, such as γ-aminobutyric acid (GABA). We compared the performances of several previously proposed algorithms using GABA-edited 1H MRS data. Given that phased-array coils often exhibit noise correlations that reduce SNR, we hypothesized that noise decorrelation algorithms would be most effective. METHODS: We examined six coil combination methods, with the second half accounting for noise correlations: 1) equal weighting; 2) signal weighting; 3) S/N2 weighting; 4) noise-decorrelated combination (nd-comb); 5) whitened singular value decomposition (WSVD); and 6) generalized least squares (GLS). Each method was applied to 119 GABA-edited MEGA-PRESS datasets acquired on 3 T GE and Siemens MRI scanners across 11 research sites. We estimated the SNR of GABA+ and N-acetylaspartate (NAA) and tested for statistical differences between the six approaches. We also calculated the intersubject coefficients of variation (CVs) of GABA+/creatine (Cr) ratios. RESULTS: There were significant differences in the SNR of GABA+ and NAA between the methods. Noise decorrelation methods produced higher SNR compared to the other approaches, with nd-comb, WSVD, and GLS yielding, on average, approximately 37 % more GABA+ and 34 % more NAA SNR than equal weighting. GLS yielded the highest SNR for both GABA+ and NAA. The CVs for GABA+/Cr were generally somewhat smaller when using noise decorrelation. CONCLUSION: As predicted, noise decorrelation coil combination, particularly GLS, produced optimal SNR for GABA-edited MRS data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

gamma-Aminobutyric AcidProton Magnetic Resonance SpectroscopyMagnetic Resonance ImagingBrainSignal-To-Noise RatioHumansAlgorithmsMagnetic Resonance SpectroscopyReproducibility of ResultsAspartic Acid

Stichwörter der Autor:innen

Coil combinationGABAMRSNoise correlationPhased-array coilsSNR

Substanzen

gamma-Aminobutyric AcidN-acetylaspartateAspartic Acid

Autor:innen und Institutionen

  • Department of Radiology, Weill Cornell Medicine, New York, NY, United States.
  • Department of Radiology, Weill Cornell Medicine, New York, NY, United States. Electronic address: mam4041@med.cornell.edu.

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Bouchard, A. E., & Mikkelsen, M. (2025). Noise decorrelation coil combination optimizes SNR of edited 1H MRS data. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110452

Vancouver

Bouchard AE, Mikkelsen M. Noise decorrelation coil combination optimizes SNR of edited 1H MRS data. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110452

BibTeX
@article{Bouchard2025,
  author = {Bouchard, Amy E and Mikkelsen, Mark},
  title = {Noise decorrelation coil combination optimizes SNR of edited 1H MRS data},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110452}
}
Kostenlos starten →