EUVIMEDEUVIMED entdecken
Open Access

Simultaneous multi‐transient linear‐combination modeling of MRS data improves uncertainty estimation

Helge Jörn Zöllner iD, Christopher Davies-Jenkins iD, Dunja Simicic iD, Assaf Tal iD, Jeremias Sulam, Georg Oeltzschner iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30110 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Helge Jörn Zöllner und 5 weiteren Autor:innen. Beteiligte Einrichtung: Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Spectroscopy, Computer Simulation, Monte Carlo Method, Algorithms. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS, NIBIB NIH HHS, National Institutes of Health (NIH).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The interest in applying and modeling dynamic MRS has recently grown. Two‐dimensional modeling yields advantages for the precision of metabolite estimation in interrelated MRS data. However, it is unknown whether including all transients simultaneously in a 2D model without averaging (presuming a stable signal) performs similarly to one‐dimensional (1D) modeling of the averaged spectrum. Therefore, we systematically investigated the accuracy, precision, and uncertainty estimation of both described model approaches.

Methods

Monte Carlo simulations of synthetic MRS data were used to compare the accuracy and uncertainty estimation of simultaneous 2D multitransient linear‐combination modeling (LCM) with 1D‐LCM of the average. A total of 2,500 data sets per condition with different noise representations of a 64‐transient MRS experiment at six signal‐to‐noise levels for two separate spin systems (scyllo‐inositol and gamma‐aminobutyric acid) were analyzed. Additional data sets with different levels of noise correlation were also analyzed. Modeling accuracy was assessed by determining the relative bias of the estimated amplitudes against the ground truth, and modeling precision was determined by SDs and Cramér‐Rao lower bounds (CRLBs).

Results

Amplitude estimates for 1D‐ and 2D‐LCM agreed well and showed a similar level of bias compared with the ground truth. Estimated CRLBs agreed well between both models and with ground‐truth CRLBs. For correlated noise, the estimated CRLBs increased with the correlation strength for the 1D‐LCM but remained stable for the 2D‐LCM.

Conclusion

Our results indicate that the model performance of 2D multitransient LCM is similar to averaged 1D‐LCM. This validation on a simplified scenario serves as a necessary basis for further applications of 2D modeling.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance SpectroscopyComputer SimulationMonte Carlo MethodAlgorithmsHumansReproducibility of ResultsLinear ModelsSensitivity and SpecificitySignal-To-Noise Ratiogamma-Aminobutyric AcidModels, Statistical

Stichwörter der Autor:innen

dynamic MRSdynamic modelingmagnetic resonance spectroscopy

Substanzen

gamma-Aminobutyric Acid

Autor:innen und Institutionen

  • Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.
  • Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel.
  • Department of Biomedical Engineering, The Johns Hopkins University, Baltimore, Maryland, USA.
  • Mathematical Institute for Data Science, The Johns Hopkins University, Baltimore, Maryland, USA.

ORCID-Profile: Helge Jörn Zöllner, Christopher Davies-Jenkins, Dunja Simicic, Assaf Tal, Georg Oeltzschner

Förderung

  • NIA NIH HHS
  • NIBIB NIH HHS
  • National Institutes of Health (NIH)

Zitieren

APA

Zöllner, H. J., Davies-Jenkins, C., Simicic, D., Tal, A., Sulam, J., & Oeltzschner, G. (2024). Simultaneous multi‐transient linear‐combination modeling of MRS data improves uncertainty estimation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30110

Vancouver

Zöllner HJ, Davies-Jenkins C, Simicic D, Tal A, Sulam J, Oeltzschner G. Simultaneous multi‐transient linear‐combination modeling of MRS data improves uncertainty estimation. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30110

BibTeX
@article{Zllner2024,
  author = {Zöllner, Helge Jörn and Davies-Jenkins, Christopher and Simicic, Dunja and Tal, Assaf and Sulam, Jeremias and Oeltzschner, Georg},
  title = {Simultaneous multi‐transient linear‐combination modeling of MRS data improves uncertainty estimation},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30110}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche