EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Multi‐Vendor and Multi‐Site Characterization of 13 C Coils for Clinical Studies

Emil S Christensen iD, Andreas Clemmensen, Esben S S Hansen iD, Jonathan Birchall, Mary A McLean, Christoffer Laustsen iD, Andreas Kjaer, Thomas L Andersen

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Emil S Christensen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Carbon Isotopes. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Lundbeck Foundation, European Union's Horizon 2020 Research, The Innovation Fund Denmark.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Due to the inherently low signal‐to‐noise ratio (SNR) domain for 13 C imaging, optimal coil performance is essential to maximize data quality. Quality control (QC) for 13 C coils employed in magnetic resonance spectroscopy (MRS) is of paramount importance. This study presents a gradient‐recalled echo (GRE) sequence alongside an image‐based analysis for SNR estimation and QC of 13 C coils.

Methods

The proposed GRE sequence (slice selective RF pulse, slice thickness 100 mm, 16 averages, 64 × 64 matrix size, 400 × 400 mm FOV, 60 Hz/px BW, 50° FA, 80 ms TR, 14 ms TE, cartesian acquisition trajectory) was comprehensively evaluated on four clinical 3 T systems, across three sites and two vendors. Thirteen coils were evaluated, including multiple surface coils (transmit/receive and receive only) and volume coils for different body parts. The GRE sequence was compared with a previously described chemical shift imaging (CSI) technique for QC of 13 C coils. The GRE sequence is widely available and built into all MR systems. In contrast, the CSI sequence is more specialized and is not available for all imaging systems.

Results

A Passing‐Bablok regression and a Spearman correlation of 0.78 demonstrated good agreement of the two methods. The GRE approach offers reduced acquisition time and simplified analysis with SNR trends demonstrating reproducible coil performance across all sites and vendors.

Conclusion

This standardization aims to strengthen multi‐center trials by ensuring data comparability and reliability, advancing the clinical translation of 13 C MRS methodologies. The results and analysis pipeline is made publicly available to facilitate implementation and coil comparisons across institutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingCarbon IsotopesHumansSignal-To-Noise RatioEquipment DesignReproducibility of ResultsPhantoms, ImagingAlgorithmsEquipment Failure AnalysisMagnetic Resonance Spectroscopy

Stichwörter der Autor:innen

13CQCcoilsphantom

Substanzen

Carbon Isotopes

Autor:innen und Institutionen

  • Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
  • Cluster for Molecular Imaging, Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Department of Clinical Medicine, The MR Research Centre, Aarhus University, Aarhus, Denmark.
  • Department of Radiology, University of Cambridge, Cambridge, UK.
  • Cancer Research UK Cambridge Centre, University of Cambridge, Cambridge, UK.
  • Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Emil S Christensen, Esben S S Hansen, Christoffer Laustsen

Förderung

  • The Lundbeck Foundation
  • European Union's Horizon 2020 Research
  • The Innovation Fund Denmark
  • The Novo Nordisk Foundation
  • Danish Cancer Society
  • The Neuroendocrine Tumor Research Foundation
  • The Neye Foundation
  • Arvid Nilssons Fond

Zitieren

APA

Christensen, E. S., Clemmensen, A., Hansen, E. S. S., Birchall, J., McLean, M. A., Laustsen, C., Kjaer, A., & Andersen, T. L. (2026). Multi‐Vendor and Multi‐Site Characterization of 13 C Coils for Clinical Studies. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70560

Vancouver

Christensen ES, Clemmensen A, Hansen ESS, Birchall J, McLean MA, Laustsen C, et al. Multi‐Vendor and Multi‐Site Characterization of 13 C Coils for Clinical Studies. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70560

BibTeX
@article{Christensen2026,
  author = {Christensen, Emil S and Clemmensen, Andreas and Hansen, Esben S S and Birchall, Jonathan and McLean, Mary A and Laustsen, Christoffer and Kjaer, Andreas and Andersen, Thomas L},
  title = {Multi‐Vendor and Multi‐Site Characterization of 13 C Coils for Clinical Studies},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70560}
}
Kostenlos starten →