Attenuation of MR spin-echo signal by restricted diffusion confined to a laminar system and a large rectangular box
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2025.110446 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Krzysztof Szymański und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Physics, University of Bialystok, Poland. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Artifacts. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: University of Bialystok.
Abstract (Originalsprache)
We investigate magnetic resonance (MR) signal attenuation caused by confined by restricted diffusion confined to a laminar system and a large rectangular box using the pulsed gradient spin-echo MR method. Applying asymptotic expansions, we derive corrections up to order 1/L2, where L is the characteristic system size, and show that in the limit of large L, the attenuation converges to the free diffusion expression. In the fast diffusion regime, where γ2G2δ2D∆≫1, interference effects become significant, limiting the applicability of the asymptotic expansion. Our findings refine diffusion-weighted MRI models and provide insights into confined molecular transport.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Physics, University of Bialystok, Poland.
- Faculty of Physics, University of Bialystok, Poland. Electronic address: l.labieniec@uwb.edu.pl.
- Faculty of Electronics and Information Technology, Warsaw University of Technology, Poland.
Förderung
- University of Bialystok
Zitieren
APA
Szymański, K., Łabieniec, Ł., Domański, G., & Bogorodzki, P. (2025). Attenuation of MR spin-echo signal by restricted diffusion confined to a laminar system and a large rectangular box. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110446
Vancouver
Szymański K, Łabieniec Ł, Domański G, Bogorodzki P. Attenuation of MR spin-echo signal by restricted diffusion confined to a laminar system and a large rectangular box. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110446
BibTeX
@article{Szymaski2025,
author = {Szymański, Krzysztof and Łabieniec, Łukasz and Domański, Grzegorz and Bogorodzki, Piotr},
title = {Attenuation of MR spin-echo signal by restricted diffusion confined to a laminar system and a large rectangular box},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2025.110446}
}
EUVIMED