EUVIMEDEUVIMED entdecken
Crossref

An accelerated alternating direction method of multiplier for MRI with TV regularisation

ZhiBin Zhu, YueHong Ding, Ying Liu, JiaQi Huang

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.110249 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von ZhiBin Zhu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Computing Science, Guilin University of Electronic Technology, Guilin 541002, PR China; Center for Applied Mathematics of G…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Guangxi Zhuang Autonomous Region Key Laboratory of Automatic Detecting Technology and Instruments, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compressed Sensing (CS) is important in the field of image processing and signal processing, and CS-Magnetic Resonance Imaging (MRI) is used to reconstruct image from undersampled k-space data. Total Variation (TV) regularisation is a common technique to improve the sparsity of image, and the Alternating Direction Multiplier Method (ADMM) plays a key role in the variational image processing problem. This paper aims to improve the quality of MRI and shorten the reconstruction time. We consider MRI to solve a linear inverse problem, we convert it into a constrained optimization problem based on TV regularisation, then an accelerated ADMM is established. Through a series of theoretical derivations, we verify that the algorithm satisfies the convergence rate of O1/k2 under the condition that one objective function is quadratically convex and the other is strongly convex. We select five undersampled templates for testing in MRI experiment and compare it with other algorithms, experimental results show that our proposed method not only improves the running speed but also gives better reconstruction results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingAlgorithmsImage Processing, Computer-AssistedHumansBrainPhantoms, ImagingData CompressionImage EnhancementSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

Alternating direction method of multiplierConvex minimization problemMagnetic resonance imagingNesterov accelerationTV regularisation

Autor:innen und Institutionen

  • School of Mathematics and Computing Science, Guilin University of Electronic Technology, Guilin 541002, PR China; Center for Applied Mathematics of Guangxi (GUET), Guilin 541002, PR China; Guangxi Colleges and Universit…
  • School of Mathematics and Computing Science, Guilin University of Electronic Technology, Guilin 541002, PR China. Electronic address: dyh19991210@163.com.
  • School of Mathematics and Computing Science, Guilin University of Electronic Technology, Guilin 541002, PR China.

Förderung

  • Guangxi Zhuang Autonomous Region Key Laboratory of Automatic Detecting Technology and Instruments
  • National Natural Science Foundation of China

Zitieren

APA

Zhu, Z., Ding, Y., Liu, Y., & Huang, J. (2024). An accelerated alternating direction method of multiplier for MRI with TV regularisation. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110249

Vancouver

Zhu Z, Ding Y, Liu Y, Huang J. An accelerated alternating direction method of multiplier for MRI with TV regularisation. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.110249

BibTeX
@article{Zhu2024,
  author = {Zhu, ZhiBin and Ding, YueHong and Liu, Ying and Huang, JiaQi},
  title = {An accelerated alternating direction method of multiplier for MRI with TV regularisation},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.110249}
}
Kostenlos starten →