High dynamic range B1+ mapping for the evaluation of parallel transmit arrays
Magnetic Resonance in Medicine · 2025-03 · 93 (3) · 1298-1305
DOI: 10.1002/mrm.30349 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 27.10.2024. Verfasst von Jörg Felder und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany. Hauptthemen laut MEDLINE: Algorithms, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helmholtz Association.
Abstract (Originalsprache)
Purpose
Demonstration of a high dynamic‐range and high SNR method for acquiring absolute maps from a combination of gradient echo and actual‐flip‐angle measurements that is especially useful during the construction of parallel‐transmit arrays.
Methods
Low flip angle gradient echo images, acquired when transmitting with each channel individually, are used to compute relative maps. Instead of computing these in a conventional manner, the equivalence of the problem to the ESPIRiT parallel image reconstruction method is used to compute maps with a higher SNR. Absolute maps are generated by calibration against a single actual flip‐angle acquisition when transmitting on all channels simultaneously.
Results
Depending on the number of receiver channels and the location of the receive elements with respect to the subject being investigated, moderate to high gains in the SNR of the acquired maps can be achieved.
Conclusions
The proposed method is especially suited for the acquisition of maps during the construction of transceiver arrays. Compared to the original method, maps with higher SNR can be computed without the need for additional measurements, and maps can also be generated using previously acquired data. Furthermore, easy adoption and fast estimation of receiver channels is possible because of existing highly optimized open‐source implementations of ESPIRiT, such as in the BART toolbox.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Neuroscience and Medicine - 4, Forschungszentrum Jülich, Jülich, Germany.
- Faculty of Medicine, RWTH Aachen University, Aachen, Germany.
- Institute of Neuroscience and Medicine - 11, Forschungszentrum Jülich, Jülich, Germany.
- JARA-BRAIN-Translational Medicine, Aachen, Germany.
- Department of Neurology, RWTH Aachen University, Aachen, Germany.
ORCID-Profile: Jörg Felder, Markus Zimmermann, N Jon Shah
Förderung
- Helmholtz Association
Zitieren
APA
Felder, J., Zimmermann, M., & Shah, N. J. (2025). High dynamic range B1+ mapping for the evaluation of parallel transmit arrays. Magnetic Resonance in Medicine, 93(3), 1298-1305. https://doi.org/10.1002/mrm.30349
Vancouver
Felder J, Zimmermann M, Shah NJ. High dynamic range B1+ mapping for the evaluation of parallel transmit arrays. Magnetic Resonance in Medicine. 2025;93(3):1298-1305. doi:10.1002/mrm.30349
BibTeX
@article{Felder2025,
author = {Felder, Jörg and Zimmermann, Markus and Shah, N Jon},
title = {High dynamic range B1+ mapping for the evaluation of parallel transmit arrays},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {3},
pages = {1298--1305},
doi = {10.1002/mrm.30349}
}
EUVIMED