EUVIMEDEUVIMED entdecken
Crossref

Complex multi-dimensional integration for T2* and R2* mapping

Yongquan Ye, Jian Xu, Zhongqi Zhang, Yan Zhang, Qiang Zhao, Jiajia Xu, Huishu Yuan

Magnetic Resonance Imaging · 2024

DOI: 10.1016/j.mri.2024.01.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Yongquan Ye und 6 weiteren Autor:innen. Beteiligte Einrichtung: United Imaging Healthcare, Houston, TX, USA. Electronic address: mqyeah@gmail.com. Hauptthemen laut MEDLINE: Algorithms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A dual Multi-Dimensional Integration (dMDI) method was proposed and demonstrated for T2* and R2* mapping. By constructing and jointly using both the original MDI term and an inversed MDI term, T2* and R2* mapping can be performed independently with intrinsic background noise suppression and spike elimination, allowing for high quantitative accuracy and robustness over a wide range of T2*. dMDI was compared to original MDI and curve fitting methods in terms of quantitative specificity, accuracy, reliability and computational efficiency. All methods were tested and compared via simulation and in vivo data. With high signal-to-noise-ratio (SNR), the proposed dMDI method yielded T2*and R2* values similar to curve fitting methods. For low SNR and background noise signals, the dMDI yielded low T2* and R2* values, thus effectively suppressing all background noise. Virtually zero spikes were observed in dMDI T2* and R2* maps in all simulation and imaging results. The dMDI method has the potential to provide improved and reliable T2* and R2* mapping results in routine and SNR-challenging scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsMagnetic Resonance ImagingReproducibility of ResultsComputer SimulationSignal-To-Noise RatioPhantoms, Imaging

Stichwörter der Autor:innen

Complex signalMDIMRIR2*RelaxometryT2*

Autor:innen und Institutionen

  • United Imaging Healthcare, Houston, TX, USA. Electronic address: mqyeah@gmail.com.
  • United Imaging Healthcare, Houston, TX, USA.
  • Beijing United Imaging Intelligent Imaging Technology Research Institute, Beijing, China.
  • Department of Radiology, Peking University Third Hospital, Beijing, China.

Zitieren

APA

Ye, Y., Xu, J., Zhang, Z., Zhang, Y., Zhao, Q., Xu, J., & Yuan, H. (2024). Complex multi-dimensional integration for T2* and R2* mapping. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.01.018

Vancouver

Ye Y, Xu J, Zhang Z, Zhang Y, Zhao Q, Xu J, et al. Complex multi-dimensional integration for T2* and R2* mapping. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.01.018

BibTeX
@article{Ye2024,
  author = {Ye, Yongquan and Xu, Jian and Zhang, Zhongqi and Zhang, Yan and Zhao, Qiang and Xu, Jiajia and Yuan, Huishu},
  title = {Complex multi-dimensional integration for T2* and R2* mapping},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.01.018}
}
Kostenlos starten →