EUVIMEDEUVIMED entdecken
Open Access

Evaluation of 0.55T MRI for Simultaneous R2* and Fat Fraction Quantification in the Presence of Hepatic Iron Overload and Steatosis Using Simulations and Phantoms

Utsav Shrestha iD, Mark Bolding, Teresa Santiago, Zachary Abramson, Cara E Morin, Aaryani Tipirneni-Sajja iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70162 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Utsav Shrestha und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The University of Memphis, Memphis, Tennessee, USA. Hauptthemen laut MEDLINE: Iron Overload, Magnetic Resonance Imaging, Fatty Liver, Liver. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To create virtual liver models simulating the concurrent presence of hepatic iron overload and steatosis based on human liver histology and to assess the accuracy and precision of R2* and fat fraction (FF) estimation at 0.55T compared to 1.5T.

Methods

Virtual liver models simulating the coexistence of iron overload and steatosis were created, encompassing clinical liver iron concentration (LIC) (0–20 mg/g) and FF (0%–30%) ranges, using morphological characteristics derived from human liver histology. MRI signals were synthesized via Monte Carlo simulations under varying SNR conditions (SNR original (SNR orig ) and SNR enhanced (SNR enh )) at 0.55T (SNR orig,0.55T = 20; SNR enh,0.55T = 50) and 1.5T (SNR orig,1.5T = 50). Simulation results were validated using iron‐fat phantoms (FF: 0%–40%; iron concentration: 0–8 μg/mL) scanned across varying SNRs using different signal averages (SNR orig,0.55T , SNR orig,1.5T = 1; SNR enh,0.55T = 4). Accuracy and precision of 0.55T for estimating R2* and FF compared to 1.5T were assessed using boxplots, heatmaps, and Kruskal–Wallis statistical tests.

Results

SNR orig,0.55T demonstrated reduced or comparable FF estimation bias relative to SNR orig,1.5T , with significantly lower bias for SNR enh,0.55T , especially for severe iron overload and FF ≤ 20%. LIC estimation for SNR orig,0.55T and SNR enh,0.55T demonstrated higher accuracy compared to SNR orig,1.5T with significant differences ( p < 0.028) for all combinations of LIC and FF except for severe iron overload with FF > 10% ( p > 0.183). Further, SNR enh,0.55T showed improved precision for FF and LIC estimation compared to SNR orig,1.5T . Phantom experiments showed reduced bias for both FF and LIC estimation for SNR enh,0.55T compared to SNR orig,1.5T .

Conclusion

0.55T shows promising results for concurrent R2 * and FF estimation, enhancing accuracy and precision compared to 1. 5 T, especially with enhanced SNR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iron OverloadMagnetic Resonance ImagingFatty LiverLiverHumansPhantoms, ImagingComputer SimulationMonte Carlo MethodSignal-To-Noise RatioImage Processing, Computer-AssistedReproducibility of ResultsAdipose TissueAlgorithmsIron

Stichwörter der Autor:innen

Monte Carlo simulationsR2*fat fractionhepatic steatosisiron overloadlower field MRIphantom

Substanzen

Iron

Autor:innen und Institutionen

  • Department of Biomedical Engineering, The University of Memphis, Memphis, Tennessee, USA.
  • Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
  • Department of Radiology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA.
  • Department of Pathology, St. Jude Children's Research Hospital, Memphis, Tennessee, USA.
  • Department of Radiology, Cincinnati Children's Hospital; Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.
  • Department of Biomedical Engineering, Department of Biomedical Sciences, University of Houston, Houston, Texas, USA.

ORCID-Profile: Utsav Shrestha, Aaryani Tipirneni-Sajja

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Shrestha, U., Bolding, M., Santiago, T., Abramson, Z., Morin, C. E., & Tipirneni-Sajja, A. (2026). Evaluation of 0.55T MRI for Simultaneous R2* and Fat Fraction Quantification in the Presence of Hepatic Iron Overload and Steatosis Using Simulations and Phantoms. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70162

Vancouver

Shrestha U, Bolding M, Santiago T, Abramson Z, Morin CE, Tipirneni-Sajja A. Evaluation of 0.55T MRI for Simultaneous R2* and Fat Fraction Quantification in the Presence of Hepatic Iron Overload and Steatosis Using Simulations and Phantoms. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70162

BibTeX
@article{Shrestha2026,
  author = {Shrestha, Utsav and Bolding, Mark and Santiago, Teresa and Abramson, Zachary and Morin, Cara E and Tipirneni-Sajja, Aaryani},
  title = {Evaluation of 0.55T MRI for Simultaneous R2* and Fat Fraction Quantification in the Presence of Hepatic Iron Overload and Steatosis Using Simulations and Phantoms},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70162}
}
Kostenlos starten →