EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI

Brian Toner iD, Ute Goerke iD, Eze Ahanonu, Kevin Johnson, Vibhas Deshpande, Holden H Wu iD, Maria I Altbach, Ali Bilgin

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1956-1971

DOI: 10.1002/mrm.70459 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 07.06.2026. Verfasst von Brian Toner und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Imaging Sciences, The University of Arizona, Tucson, AZ, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science Foundation, Technology and Research Initiative Fund (TRIF) Improving Health Initiative, NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Purpose: Dictionary matching is a standard tool in quantitative MRI (qMRI), but typically lacks uncertainty quantification (UQ). This is critical when advanced reconstructions (e.g., compressed sensing, deep learning) introduce complex‐valued, spatially varying, and temporally correlated noise that violates standard assumptions of independent and identically distributed (iid) noise.

Methods

Two voxel‐wise uncertainty methods: a frequentist Likelihood Ratio Test (LRT) and a Bayesian marginal posterior approach, are introduced. Noise is modeled as spatially varying and temporally correlated using the covariance estimated from background regions. Methods were validated via simulations and phantom experiments using radial turbo spin‐echo ( mapping) and radial Look‐Locker ( mapping). In vivo experiments characterized uncertainty under varying acceleration factors.

Results

Simulations confirmed both methods achieve nominal coverage rates (e.g., 95% intervals containing the true value 95% of the time) where standard iid assumptions fail. Phantom results showed excellent agreement with gold‐standard spin‐echo references. In vivo experiments highlighted that higher acceleration factors widen uncertainty intervals for and . The LRT method proved more computationally efficient than the Bayesian approach while providing comparable interval estimates.

Conclusion

A robust framework is presented for UQ in dictionary‐matched qMRI. By modeling the non‐iid noise inherent in modern reconstructions, these methods provide statistically interpretable UQ that assesses the reliability of parameter maps in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingImage Processing, Computer-AssistedReproducibility of ResultsPhantoms, ImagingHumansUncertaintyAlgorithmsBayes TheoremComputer SimulationBrainSignal-To-Noise Ratio

Stichwörter der Autor:innen

quantitative MRIuncertainty quantification

Autor:innen und Institutionen

  • Department of Radiology and Imaging Sciences, The University of Arizona, Tucson, AZ, USA.
  • Program in Applied Mathematics, The University of Arizona, Tucson, AZ, USA.
  • MR R&D Collaborations, Siemens Medical Solutions, Phoenix, AZ, USA.
  • Department of Electrical and Computer Engineering, The University of Arizona, Tucson, AZ, USA.
  • MR R&D Collaborations, Siemens Medical Solutions, Houston, TX, USA.
  • Department of Bioengineering, University of California Los Angeles, Los Angeles, CA, USA.

ORCID-Profile: Brian Toner, Ute Goerke, Holden H Wu

Förderung

  • National Science Foundation
  • Technology and Research Initiative Fund (TRIF) Improving Health Initiative
  • NCI NIH HHS
  • NIH HHS
  • Arizona Biomedical Research Centre
  • NIBIB NIH HHS
  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Toner, B., Goerke, U., Ahanonu, E., Johnson, K., Deshpande, V., Wu, H. H., Altbach, M. I., & Bilgin, A. (2026). Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI. Magnetic Resonance in Medicine, 96(4), 1956-1971. https://doi.org/10.1002/mrm.70459

Vancouver

Toner B, Goerke U, Ahanonu E, Johnson K, Deshpande V, Wu HH, et al. Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI. Magnetic Resonance in Medicine. 2026;96(4):1956-1971. doi:10.1002/mrm.70459

BibTeX
@article{Toner2026,
  author = {Toner, Brian and Goerke, Ute and Ahanonu, Eze and Johnson, Kevin and Deshpande, Vibhas and Wu, Holden H and Altbach, Maria I and Bilgin, Ali},
  title = {Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1956--1971},
  doi = {10.1002/mrm.70459}
}
Kostenlos starten →